Sharp Electronics (UK) Limited
Originator AvW Supervisor Approval Date / / Reference TB9312136
Revision
White – Carry out as required, Yellow – Carry out as required and whenever the unit comes in for service, Red – Carry out on all units
R2V15-002
Month of Issue:
Classification: Routine
MICROWAVE TECHNICAL BULLETIN
Page 1 of 1
MODELS
R2V15M
R3A55M
REASON
During manufacture the Fan Duct configuration ( items 4-5 and 4-6 ) has been change
to one part.
to one part.
ACTION
When replacing a two piece Fan Duct Assembley, follow the procedure outlined
below.
below.
1. Remove the Fan Duct ( item 4-5 ) and Fan Duct B ( item 4-6 ).
2. Remove the Fan Motor as described in the service manual.
3. Secure the Fan Motor to the new Fan Duct using the screws and nuts in the parts
2. Remove the Fan Motor as described in the service manual.
3. Secure the Fan Motor to the new Fan Duct using the screws and nuts in the parts
list belwo. Two screws and nuts are required.
4. Drill a 5mm diameter hole in the rear cavity to accept mounting screws.
5. Locate the fan duct tabs into the back plate.
6. Screw the Fan Duct Assembly to the hole drilled in step 4.
7. Refit the Fan Motor wires.
5. Locate the fan duct tabs into the back plate.
6. Screw the Fan Duct Assembly to the hole drilled in step 4.
7. Refit the Fan Motor wires.
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
-
New Fan Duct
PDUC-A574WRFO
AL
-
Screw
XBPSD40P25000
AA
-
Nut
XNESD40-32000
AA