R-362M (serv.man2) - Sharp Home Appliance Service Manual (repair manual). Page 10

Read Sharp R-362M (serv.man2) Service Manual online

R362M - 10
  TOUCH CONTROL PANEL ASSEMBLY
OUTLINE OF TOUCH CONTROL PANEL
3) Synchronizing Signal Circuit
The power source synchronizing signal is available in
order to compose a basic standard time in the clock
circuit. It accompanies a very small error because it
works on commercial frequency.
4) ACL
A circuit to generate a signal which resets the LSI to the
initial state when power is supplied.
5) Buzzer Circuit
The buzzer is responsive to signals from the LSI to
emit audible sounds (key touch sound and completion
sound).
6) Door Sensing Switch (Stop Switch)
A switch to "tell" the LSI if the door is open or closed.
7) Relay Circuit
To drive the magnetron, fan motor, turntable motor
and  light the oven lamp.
8) Back Light Circuit
A circuit to drive the back light (Light emitting diodes
LD1 - LD10).
9)  Indicator Circuit
This circuit consists of 7-digits, 39-segments and 3-
common electrodes using a Liquid Crystal Display.
10) Absolute Humidity Sensor Circuit
This circuit detects the humidity of a food which
is being cooked, to control its automatic cooking.
The touch control section consists of the following units as
shown in the touch control panel circuit.
(1) Key Unit
(2) Control Unit (The Control unit consists of Power unit and
CPU unit.)
The principal functions of these units and signals communi-
cated among them are explained below.
Key Unit
The key unit is composed of a matrix, signals generated in the
LSI are sent to the key unit from P40, P41, P72, P73 P74, P75,
P76 and P77.
When a key pad is touched, a signal is completed through the
key unit and passed back to the LSI through P44 - P47 to
perform the function that was requested.
Control Unit
Control unit consists of LSI, power source circuit, synchroniz-
ing signal circuit, ACL circuit, buzzer circuit, relay circuit,
temperature measurement circuit, indicator circuit, absolute
humidity sensor circuit and back light circuit.
1) LSI
This LSI controls the temperature measurement signal,
AH sensor signal, key strobe signal, relay driving signal
for oven function and indicator signal.
2) Power Source Circuit
This circuit generates voltage necessary in the control
unit.
Symbol
Voltage
Application
VC
-5.2V
LSI(IC1)
Page of 28