R-360AM - Sharp Home Appliance Service Manual (repair manual). Page 9

Read Sharp R-360AM Service Manual online

R360AM - 9
29
R13
IN
Signal similar to R03.
When either G9 line on key matrix is touched, a corresponding signal will be input into
R13.
30
R20
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R03, R11, R12 and R13
terminal while one of G8 line keys on key matrix is touched.
31
R21
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R03, R11, R12 and R13
terminal while one of G7 line keys on key matrix is touched.
32
R22
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R03, R11, R12 and R13
terminal while one of G6 line keys on key matrix is touched.
33
R23
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R03, R11, R12 and R13
terminal while one of G5 line keys on key matrix is touched.
34
R60
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R03, R11, R12 and R13
terminal while one of G4 line keys on key matrix is touched.
35
R61
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R03, R11, R12 and R13
terminal while one of G3 line keys on key matrix is touched.
36
R62
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R03, R11, R12 and R13
terminal while one of G2 line keys on key matrix is touched.
37
R63
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to R03, R11, R12 and R13
terminal while one of G1 line keys on key matrix is touched.
38-40
R70-R72
OUT
Terminal not used.
41-43
SEG20-SEG22
OUT
Terminal not used.
44-65
SEG23-SEG44
OUT
Segment data signals.
Connected to LCD.
The relation between signals are as follows:
LSI Signal (Pin No.)
LCD (Pin No.)
LSI Signal (Pin No.)
LCD (Pin No.)
SEG 23 (44) .......................... SEG 1
SEG 34 (55) ....................... SEG 12
SEG 24 (45) .......................... SEG 2
SEG 35 (56) ....................... SEG 13
SEG 25 (46) .......................... SEG 3
SEG 36 (57) ....................... SEG 14
SEG 26 (47) .......................... SEG 4
SEG 37 (58) ....................... SEG 15
SEG 27 (48) .......................... SEG 5
SEG 38 (59) ....................... SEG 16
SEG 28 (49) .......................... SEG 6
SEG 39 (60) ....................... SEG 17
SEG 29 (50) .......................... SEG 7
SEG 40 (61) ....................... SEG 18
SEG 30 (51) .......................... SEG 8
SEG 41 (62) ....................... SEG 19
SEG 31 (52) .......................... SEG 9
SEG 42 (63) ....................... SEG 20
SEG 32 (53) ........................ SEG 10
SEG 43 (64) ....................... SEG 21
SEG 33 (54) ........................ SEG 11
SEG 44 (65) ....................... SEG 22
66
COM1
OUT
Common data signal: COM1.
Connected to LCD (Pin No. COM1).
67
COM2
OUT
Common data signal: COM2.
Connected to LCD (Pin No. COM2).
68
COM3
OUT
Common data signal: COM3.
Connected to LCD (Pin No. COM3).
69
COM4
OUT
Terminal not used.
70-72
V1-V3
IN
Power source voltage input terminal.
Standard voltage for LCD.
73
VCC
IN
Connected to GND.
74
AVCC
IN
Connected to GND.
75-78
AN1-AN3
IN
Terminal to change cooking constant according to the Model.
By using the A/D converter contained in the LSI, DC voltage in accordance with the
Model in operation is applied to set up its cooking constant.
79
AN4
IN
Terminal not used.
80
AN5
IN
To input signal which communicates the door open/close information to LSI.
Door closed; "H" level signal (0V).
Door opened; "L" level signal (-5V)
Pin No.
Signal
I/O
Description
TOUCH CONTROL PANEL ASSEMBLY
Page of 23
Display

Click on the first or last page to see other R-360AM service manuals if exist.