SERVICING
 TOUCH CONTROL PANEL ASSEMBLY
approx. 1M ohm
1. Precautions for Handling Electronic Components
This unit uses CMOS LSI in the integral part of the
circuits. When handling these parts, the following
precautions should be strictly followed. CMOS LSI
have extremely high impedance at its input and
output terminals. For this reason, it is easily influenced
by the surrounding high voltage power source, static
electricity charge in clothes, etc., and sometimes it is
not fully protected by the built-in protection circuit.
In order to protect CMOS LSI.
1) When storing and transporting, thoroughly wrap
them in aluminium foil. Also wrap PW boards
containing them in aluminium foil.
2) When soldering, ground the technician as shown
in the figure and use grounded soldering iron
and work table.
2. Servicing of Touch Control Panel
We describe the procedures to permit servicing of the
touch control panel of the microwave oven and the
precautions you must take when doing so.
To perform the servicing, power to the touch control
panel is available either from the power line of the
oven itself or from an external power source.
(1) Servicing the touch control panel with power
supply of the oven :
CAUTION:
THE HIGH VOLTAGE TRANSFORMER OF THE
MICROWAVE OVEN IS STILL LIVE DURING
SERVICING AND PRESENTS A HAZARD .
Therefore, when checking the performance of
the touch control panel, put the outer cabinet on
the oven to avoid touching the high voltage
transformer, or unplug the primary terminal
(connector) of the high voltage transformer to
turn it off; the end of such connector must be
insulated with an insulating tape. After servicing,
be sure to replace the leads to their original
locations.
A.
 On some models, the power supply cord
between the touch control panel and the oven
itself is so short that the two can't be separated.
For those models, check and repair all the
controls (sensor-related ones included) of the
touch control panel while keeping it connected
to the oven.
B.
 On some models, the power supply cord
between the touch control panel and the oven
proper is so long enough that they may be
separated from each other.
For those models, therefore, it is possible to check
and repair the controls of the touch control panel while
keeping it apart from the oven proper; in this case you
must short both ends of the door sensing switch (on
PWB) of the touch control panel with a jumper, which
brings about an operational state that is equivalent to
the oven door being closed. As for the sensor-related
controls of the touch control panel, checking them is
possible if the dummy resistor(s) with resistance equal
to that of the controls are used.
(2) Servicing the touch control panel with power
supply from an external power source:
Disconnect the touch control panel completely from
the oven proper, and short both ends of the door
sensing switch (on PWB) of the touch control panel,
which brings about an operational state that is
equivalent to the oven door being closed. Connect an
external power source to the power input terminal of
the touch control panel, then it is possible to check
and repair the controls of the touch control panel; it is
also possible to check the sensor-related controls of
the touch control panel by using the dummy resistor(s).
3. Servicing Tools
Tools required to service the touch control panel assembly.
1) Soldering iron: 30W
(It is recommended to use a soldering iron with a
grounding terminal.)
2) Oscilloscope: Single beam, frequency range: DC -
10MHz type or more advanced model.
3) Others: Hand tools
4. Other Precautions
1) Before turning on the power source of the control
unit, remove the aluminium foil applied for preventing
static electricity.
2) Connect the connector of the key unit to the control
unit being sure that the lead wires are not twisted.
3) After aluminium foil is removed, be careful that
abnormal voltage due to static electricity etc. is not
applied to the input or output terminals.
4) Attach connectors, electrolytic capacitors, etc. to
PWB, making sure that all connections are tight.
5) Be sure to use specified components where high
precision is required.
Page of 15