R-345M (serv.man3). text - Sharp Home Appliance Service Manual (repair manual). Page 10

Read Sharp R-345M (serv.man3) Service Manual online

R345M - 10
20.0 msec
H : +5V
L : 0V
HIGH
H : +5V
L : 0V
H : +5V
L : 0V
MEDIUM
HIGH
ON
ON
OFF
OFF
OFF
24 sec.
8 sec.
A
B
0.1 sec.
2 sec.
H : +5V
L: 0V
H : +5V
L: 0V
1-12
SEG0 -
OUT
Segment data signal.
SEG11
Connected to LCD.
The relation between signals are as follows:
LSI signal (Pin No.)
LCD (Pin No.)
LSI signal (Pin No.) LCD (Pin No.)
SEG 0 (1) .............................. S12(4)
SEG 6 (7) ............................ S6(10)
SEG 1 (2) .............................. S11(5)
SEG 7 (8) ............................ S5(11)
SEG 2 (3) .............................. S10(6)
SEG 8 (9) ............................ S4(12)
SEG 3 (4) ................................ S9(7)
SEG 9 (10) .......................... S3(13)
SEG 4 (5) ................................ S8(8)
SEG 10 (11) ........................ S2(14)
SEG 5 (6) ................................ S7(9)
SEG 11 (12) ........................ S1(15)
13
R60
OUT
Tact switch strobe signal.
Signal applied to tact switch section. A pulse signal is input to R81 terminal while
the tact switch SW4 or the tact switch SW5 is touched.
14
R61
OUT
Tact switch strobe signal.
Signal applied to tact switch section. A pulse signal is input to R81 terminal while
the tact switch SW3 or the tact switch SW7 is touched.
15
R62
OUT
Tact switch strobe signal.
Signal applied to tact switch section. A pulse signal is input to R81 terminal while
the tact switch SW2 or the tact switch SW6 is touched.
16
R63
OUT
Tact switch strobe signal.
Signal applied to tact switch section. A pulse signal is input to R81 terminal while
the tact switch SW1 is touched.
17
AIN0
IN
To input signal which communicates the door open/close information to LSI.
Door close "L" level signal (0V).  Door open "H" level (+5V)
18-20
AIN1-AIN3
IN
Terminal to change functions according to the Model.
By using the A/D converter contained in the LSI, DC voltage in accordance with the
Model in operation is applied to set up its function.
21
VSS
IN
Power source voltage: 0V.
VSS voltage of power source circuit input.
22
R70
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2).
The signals holds "L" level during micro-
wave cooking and "H" level while not cook-
ing. In other cooking modes (variable cook-
ing) the signal turns to  "H" level and "L"
level in  repetition according to the power
level.
23
R71
OUT
Signal to sound buzzer (2.0 kHz).
A: key touch sound.
B: Completion sound.
24
R72
OUT
Oven lamp, fan motor and turntable motor driving signal.
To turn on and off shut off relay (RY1). The
square waveform voltage is delivered to
the RY1 driving circuit.
25
R73
IN
Signal coming from tact switch.
When either of tact switches SW5-SW7 is touched, a corresponding signal out of
R60,R61 and R62 will be input into R73. When no key is touched, the signal is held
at "H" level
LSI(IZA919DR)
The I/O signal of the LSI(IZA919DR) are detailed in the following table.
  Pin No.
 Signal
 I/O
                                                  Description
DESCRIPTION OF LSI
Page of 14
Display