R-334 (serv.man4). Complete - Sharp Home Appliance Service Manual (repair manual). Page 15

Read Sharp R-334 (serv.man4) Service Manual online

R-334 - 15
6. Measure the final water temperature. (Example: The final temperature T2 = 21
°
C)
7. Calculate the microwave power output P in watts from above formula.
Initial temperature .........................................................................................................  T1 = 11
°
C
Temperature after (46.5 + 3) = 49.5 sec. ......................................................................  T2 = 21
°
C
Temperature difference Cold-Warm ............................................................................  
T1 = 10
°
C
Measured output power
The equation is “P = 90 x 
T” .............................................................. P = 90 x 10
°
C = 900 Watts
JUDGEMENT:  The measured output power should be at least 
±
 15 % of the rated output power.
CAUTION: 1
°
C CORRESPONDS TO 90 WATTS. REPEAT MEASUREMENT IF THE POWER IS
INSUFFICIENT.
CARRY OUT 3D CHECKS
Disconnect the leads to the primary winding of the power transformer.  Disconnect the filament and
secondary winding connections from the rest of the HV circuitry. Using an ohmmeter,  set on a low range,
it is possible to check the continuity of all three windings. The following readings should be obtained:-
a. Primary winding ............ 1.9 ohms approximately
b. Secondary winding ....... 120 ohms approximately
c. Filament winding ........... less than 1 ohm
If the reading obtained are not stated above, then the power transformer is probably faulty and should
be replaced.
CARRY OUT 4R CHECKS
PROCEDURE
LETTER
COMPONENT TEST
HIGH VOLTAGE RECTIFIER TEST
CARRY OUT 3D CHECKS.
Isolate the high voltage rectifier assembly from the HV circuit. The high voltage rectifier  can be tested
using an ohmmeter set to its highest range. Connect the ohmmeter across the terminal B + C of the high
voltage rectifier and note the reading obtained. Reverse the meter leads and note this second reading.
The normal resistance is infinite in one direction and more than 100 k
 in the other direction.
WARNING: High voltages and large currents are present at the secondary winding and
filament winding of the power transformer.   It is very dangerous to work near
this part when the oven is on.   NEVER make any voltage measurements of the
high-voltage circuits,  including the magnetron filament.
B
POWER TRANSFORMER TEST
C
HIGH VOLTAGE RECTIFIER ASSEMBLY TEST
Heat up for 49.5 sec.
TEST PROCEDURES (CONT.)
1000g
1000g
1000g
T1˚C
T2˚C
Page of 40