2.  Install the earth wire lead of power supply cord to the oven 
cavity back plate with one (1) screw and tight the screw.
3.  Connect the brown and blue wire leads of power supply cord 
to the noise filter correctly, referring to the Pictorial Diagram.
Power Supply
Cord
Oven Cavity
Back Plate
Square
Hole
Moulding
Cord Stopper
Figure C-3(b) Power Supply Cord Replacement
2. REINSTALL
Insert the moulding cord stopper of power supply cord into 
the square hole of the rear cabinet, referring to the Figure 
C-3 (b).
Power Supply
Cord
Oven Cavity
Back Plate
Screw
Green/Yellow
Wire
Brown Wire
Blue
Wire
Fuse Holder Assembly
TH
W
DE
R
L
N
 
 
Figure C-3(a) Power Supply Cord Replacement
1.
[10] CONTROL PANEL ASSEMBLY REMOVAL
CARRY OUT  3D  CHECKS.
Disconnect the leads from the control unit.
Remove the one (1) screw holding the control panel to the 
front panel of the oven cavity.
1.
2.
3.
Lift up the control panel assembly and release it from the 
oven cavity.
Now, the control panel assembly is free.
4.
5.
[11] GRAPHIC SHEET AND MEMBRANE SWITCH REPLACEMENT
1. REMOVAL
CARRY OUT  3D  CHECKS.
Remove the control panel assembly, referring to chapter of 
CONTROL PANEL ASSEMBLY REMOVAL.
Disconnect the ribbon cable of the membrane switch from 
the connector (CN-G) on the control unit.
Tear away the graphic sheet from the control panel frame.
Tear away the membrane switch from the control panel 
frame.
2. REINSTALL
Remove remaining adhesive on the control panel frame sur-
faces with a soft cloth soaked in alcohol.
Tear the backing paper from the new membrane switch.
Insert the ribbon cable of the membrane switch into the slit 
of the control panel frame.
Adjust the upper edge and right edge of the membrane 
switch to the small depression on the surface of the control 
panel frame.
Attach the membrane switch to the control panel frame by 
rubbing with a soft cloth not to scratch.
Tear the backing paper from the new graphic sheet.
Adjust the upper edge and right edge of the graphic sheet 
to the large depression on the surface of the control panel 
frame.
Attach the graphic sheet to the control panel frame by rub-
bing with a soft cloth not to scratch.
Connect the ribbon cable of the membrane switch to the 
connector (CN-G) on the control unit.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
6.
7.
8.
9.
NOTE: Do not contact the contact surface of the ribbon 
cable (edge) and the rubber connector directly with 
your fingers. This is to avoid oxidized. If display digits 
are missing or scrambled, remove control unit and  
clean contact surface with alcohol. After cleaning, 
do not attach the rubber connector until alcohol 
dries up. Do not use alcohol or solution to clean the 
rubber connector. Make sure that there is no trash 
or foreign substance on contact surface of the rubber 
connector.
Graphic sheet
Ribbon
cable
Connector
(CN-G)
Small depression
Control panel frame
Slit
Control unit
Membrane
switch
Ribbon
cable
Large
depression
Figure C-4. Graphic Sheet and Membrane Switch Replacement