4.  Examine when the oven at operating, but the food can’t be heated 
Pull out the power plug, take off the outer case, discharge the capacitor, measure the resistance value of the primary winding and 
the secondary winding of the transformer with a multi meter
 
(FIG.5-3 and FIG.5-4). The resistance value of the primary winding 
should be about 2.2 ohm, the secondary winding should be about 130 ohm, otherwise, it indicates the transformer has broken, 
and should be replaced by a new one. 
If the transformer is normal, then the high voltage capacitor should be checked. Pull out the connecting plug of the capacitor, 
and measure it with Rx1 grade of a multi meter, the two rod of the multi meter connect the two polarity of the capacitor. When 
they just connected, the reading of the multi meter should be zero, then enlarge to nine mega ohm slowly. Change the rod to 
different polarity, the reading repeat from zero to 9 mega ohm (FIG.5-5),it means the capacitor is normal. If the indicator of the 
multi meter can’t point out from zero to 9  mega ohm, it indicates the high voltage capacitor has broken, and should be 
replaced by a new one. 
 
 
 
 
 
 
 
 
 
If it is normal between the two pole of the capacitor, then the insulation between the capacitor pole and the cabinet (FIG.5-6) 
should be checked. 
If the resistance value between the capacitor pole and the cabinet is “∞”,the capacitor is normal. Then check the earth of the 
magnetron’s two filament to see whether they are short-circuited (FIG.5-7).If they are short-circuited and the filament strikes 
the shell of the magnetron, it indicates the magnetron has broken, and should be replaced by a new, same model one. 
If there is no problem with the magnetron, check the high voltage diode then. Measure the diode with Rx10k grade of a multi 
meter, the “-” rod end of the multi meter connect the cathode of diode, the “+ “ rod end of the multi meter connect the anode of 
the diode(FIG.5-8).The multi meter reading should be about 150 thousand ohm. Then change the rod to different 
electrode(FIG.5-9), the reading should be “∞”.If the reading is very small, and near to short circuit, it indicates the high 
voltage diode has been punctured, and should be replaced by a new one. 
If high voltage diode is also normal, then test the pilot switch(FIG.5-10). Pull out the two plugs of the switch, Measure it with 
the Rx1 grade of a multi meter, the two rod connect the plug of the switch, the resistance value should be “∞”.Then press 
down the pilot switch with a screwdriver, if the reading of the multi meter pointed to zero, it indicates the pilot switch has 
broken, and should replace it with a new, same model one.
 
5-5 
FIG5-6 
 
FIG5-5 
FIG5-3 
FIG5-4 