7. Release two (2) pins of door panel from two (2) holes of upper and
lower oven hinges by lifting up.
8. Now, door panel with door frame is free from oven cavity.
9. Release door panel from ten (10) tabs of door frame and remove
the door frame by sliding the door panel downward.
10.Now, door panel with sealer film is free.
11.Tear sealer film from door panel.
12.Now, door panel is free.
13.Slide latch head upward and remove it from door frame with releas-
ing latch spring from door frame and latch head.
14.Now, latch head and latch spring are free.
15.Remove the two (2) screw holding the door handle and the glass
stopper to the door frame.
16.Remove the door handle and the glass stopper from the door
frame.
17.Remove the door glass from the door frame by sliding the door
glass rightwards.
18.Now, door glass is free.
2. REINSTALLATION
1. Insert door glass into the door frame by sliding leftwards.
2. Re-install the glass stopper and the door handle to the door frame
with the two (2) screws.
3. Re-install latch spring to the head. Re-install latch spring to the
door frame. Re-install latch head to the door frame.
4. Re-install door panel to door frame by fitting ten (10) tabs of door
frame to ten (10) holes of door panel.
5. Put sealer film on door panel. Refer to “Sealer Film” about how to
handle new one.
6. Catch two (2) pins of door panel on two (2) hole of upper and lower
oven hinges
7. Re-install choke cover to door panel by pushing.
NOTE: After any service to the door;
1) Make sure that 1st. latch switch, 2nd. interlock relay control
switch and monitor switch are operating properly. (Refer to
chapter “Test Procedures”.).
2) An approved microwave survey meter should be used to
assure compliance with proper microwave radiation emission
limitation standards.
3. After any service, make sure of the following:
1. Door latch heads smoothly catch latch hook through latch holes
and that latch head goes through center of latch hole.
2. Deviation of door alignment from horizontal line of cavity face plate
is to be less than 1.0mm.
3. Door is positioned with its face pressed toward cavity face plate.
4. Check for microwave leakage around door with an approved micro-
wave survey meter. (Refer to Microwave Measurement Procedure).
NOTE: The door on a microwave oven is designed to act as an
           Figure C-7. Door Replacement
4. SEALER FILM
1. Put the adhesive tape on the backing film of the sealer film as
shown in Fig. C-8
2. Tear the backing film by pulling the adhesive tape.
3. Put the pasted side of the sealer film on the door panel
                              Figure C-8. Sealer film
Upper Oven
Hinge
Lower
Oven Hinge
Pin
Upper
Oven Hinge
Slit choke of
door panel
Choke Cover
Pin
Lower Oven
Hinge
Sealer film
Backing film