R-254M (serv.man2). Part 1 Text (1-25) - Sharp Home Appliance Service Manual (repair manual). Page 17

Read Sharp R-254M (serv.man2) Service Manual online

R-254M - 17
Pin No.
Signal
I/O
Description
27
RESET
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied.
Temporarily set "L" level the moment power is applied, at this time the LSI is reset.
Thereafter set at "H" level.
28-29
P71-P70
OUT
Terminal not used.
30
XIN
IN
Internal clock oscillation frequency input setting.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit
with respect to XOUT terminal.
31
XOUT
OUT
Internal clock oscillation frequency control output.
Output to control oscillation input of XIN.
32
VSS
IN
Power source voltage: -5.0V.
VC voltage of power source circuit input.
33
P27
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43, P44, P45 and
P46 terminal while one of G1 line keys on key matrix is touched.
34
P26
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43, P44, P45 and
P46 terminal while one of G2 line keys on key matrix is touched.
35
P25
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43, P44, P45 and
P46 terminal while one of G3 line keys on key matrix is touched.
36
P24
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43, P44, P45 and
P46 terminal while one of G4 line keys on key matrix is touched.
37
P23
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43, P44, P45 and
P46 terminal while one of G5 line keys on key matrix is touched.
38
P22
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43, P44, P45 and
P46 terminal while one of G6 line keys on key matrix is touched.
39
P21
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43, P44, P45 and
P46 terminal while one of G7 line keys on key matrix is touched.
40
P20
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to P43, P44, P45 and
P46 terminal while one of G8 line keys on key matrix is touched.
41-56
P17-P00
OUT
Terminal not used.
57-60
P37-P34
OUT
Terminal not used.
61-72
SEG11-SEG0
OUT
Segment data signal.
Connected to LCD.
The relation between signals are as follows:
LSI signal (Pin No.) LCD segment
LSI signal (Pin No.) LCD segment
SEG 11 (61) ............................ S12
SEG   5 (67) .............................. S6
SEG 10 (62) ............................ S11
SEG   4 (68) .............................. S5
SEG   9 (63) ............................ S10
SEG   3 (69) .............................. S4
SEG   8 (64) ............................   S9
SEG   2 (70) .............................. S3
SEG   7 (65) ............................   S8
SEG   1 (71) .............................. S2
SEG   6 (66) ............................   S7
SEG   0 (72) .............................. S1
73/74
VCC/VREF
IN
Connected to GND.
75
AVSS
IN
Connected to VC.
76
COM3
OUT
Terminal not used.
77
COM2
OUT
Common data signal.
Connected to LCD signal C3.
LSI(IXA083DR)
The I/O signal of the LSI(IXA083DR) are detailed in the following table.
DESCRIPTION OF LSI
Page of 25
Display