R-24STM (serv.man2). Part 1 Text (1-20) - Sharp Home Appliance Service Manual (repair manual). Page 16

Read Sharp R-24STM (serv.man2) Service Manual online

R-24STM - 16
Coil
Gap
Rotor
Bracket
Stator
Groove joint pliers
Shaft
Axis
Stator
Rotor
These are the position 
where should be 
pinched with pliers
Shaft
Table
Center of 
bracket
1. CARRY OUT 3D CHECKS.
2. Disconnect the wire lead from the oven lamp, referring
to "Positive lock
®
 connector removal".
3. Lift up the oven lamp from the clips of the air intake duct.
4. Now, the oven lamp is free.
Figure C-1 (a) Replacement of Power Supply Cord
Figure C-1(b). Replacement of Power Supply Cord
Oven lamp
POWER SUPPLY CORD REPLACEMENT
Removal
1. CARRY OUT 3D CHECKS.
2. Remove the one (1) screw and nut holding the green/
yellow wire to the oven cavity.
3. Disconnect the leads of the power supply cord from the
noise filter, referring to the Figure C-1(a).
4. Release the power supply cord from the rear cabinet.
5. Now, the power supply cord is free.
Re-install
1. Insert the moulding cord stopper of power supply cord
into the square hole of the rear cabinet, referring to the
Power supply cord
Oven cavity 
back plate
Green / Yellow
Wire
Brown Wire
Noise filter
Chassis
support
Blue Wire
Figure C-1(b). Installation of Power supply cord.
2. Install the earth wire lead of power supply cord to the
oven cavity with one (1) screw and nut and tighten.
3. Connect the brown and blue wire leads of power supply
cord to the noise filter correctly, referring to the Pictorial
Diagram.
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE
3. Re-connect the wire leads to the fan motor, referring to the
pictorial diagram.
OVEN LAMP REMOVAL
CAUTION: WHEN YOU (SERVICE ENGNEERS) CON-
NECT THE POSITIVE LOCK
®
 CONNEC-
TORS TO THE TERMINALS, CONNECT THE
POSITIVE LOCK
®
 SO THAT THE LEVER
FACES YOU.
Terminal
Push
Pull down
1
2
Lever
Positive lock®
connector
 Positive lock
®
connector
3. Pull down on the positive lock
®
 connector.
Rear view
Side view
1. CARRY OUT 3D CHECKS.
2. Push the lever of positive lock
®
 connector.
POSITIVE LOCK
®
  CONNECTOR REMOVAL
Lock
Socket
Bulb
OVEN CAVITY
BACK PLATE
SQUARE HOLE
MOULDING
CORD
STOPPER
POWER SUPPLY
CORD
GROMMET
MOULDING
Page of 20
Display