R-242M - Sharp Home Appliance Service Manual (repair manual). Page 9

Read Sharp R-242M Service Manual online

R-242M - 9
Pin No.
Signal
I/O
Description
HIGH
H : +5V
L : 0V
H : +5V
L : 0V
MEDIUM
HIGH
ON
ON
OFF
OFF
OFF
24 sec.
8 sec.
A
B
0.1 sec.
2 sec.
H : +5V
L: 0V
H : +5V
L: 0V
20.0 msec
During cooking
H : +5V
L : 0V
1-12
SEG0 -
OUT
Segment data signal.
SEG11
Connected to LCD.
The relation between signals are as follows:
LSI signal (Pin No.)
LCD (Pin No.)
LSI signal (Pin No.)
LCD (Pin No.)
SEG 0 (1) ............................ S6(4)
SEG 6 (7) ..................... S12(10)
SEG 1 (2) ............................ S7(5)
SEG 7 (8) ....................... S5(11)
SEG 2 (3) ............................ S8(6)
SEG 8 (9) ....................... S4(12)
SEG 3 (4) ............................ S9(7)
SEG 9 (10) ..................... S3(13)
SEG 4 (5) .......................... S10(8)
SEG 10 (11) ................... S2(14)
SEG 5 (6) .......................... S11(9)
SEG 11 (12) ................... S1(15)
13
R60
OUT
Tact switch strobe signal.
Signal applied to tact switch section. A pulse signal is input to R81 terminal while
the tact switch SW4 or the tact switch SW5 is touched.
14
R61
OUT
Tact switch strobe signal.
Signal applied to tact switch section. A pulse signal is input to R81 terminal while
the tact switch SW3 or the tact switch SW7 is touched.
15
R62
OUT
Tact switch strobe signal.
Signal applied to tact switch section. A pulse signal is input to R81 terminal while
the tact switch SW2 or the tact switch SW6 is touched.
16
R63
OUT
Tact switch strobe signal.
Signal applied to tact switch section. A pulse signal is input to R81 terminal while
the tact switch SW1 is touched.
17
AIN0
IN
To input signal which communicates the door open/close information to
LSI.
Door close "L" level signal (0V).  Door open "H" level (+5V)
18-20
AIN1-AIN3
IN
Terminal to change functions according to the Model.
By using the A/D converter contained in the LSI, DC voltage in accordance with
the Model in operation is applied to set up its function.
21
VSS
IN
Power source voltage: 0V.
VSS voltage of power source circuit input.
22
R70
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2).
The signals holds "L" level during micro-
wave cooking and "H" level while not
cooking. In other cooking modes (vari-
able cooking) the signal turns to "H"
level and "L" level in repetition accord-
ing to the power level.
23
R71
OUT
Signal to sound buzzer (2.0 kHz).
A: key touch sound.
B: Completion sound.
24
R72
OUT
Oven lamp, fan motor and turntable motor driving signal.
To turn on and off shut off relay (RY1).
The square waveform voltage is deliv-
ered to the RY1 driving circuit.
25
R73
IN
Signal coming from tact switch.
When either of tact switches SW5-SW7 is touched, a corresponding signal out
of R60,R61 and R62 will be input into R73. When no key is touched, the signal
is held at "H" level.
DESCRIPTION OF LSI
LSI(IZA787DR)
The I/O signal of the LSI(IZA787DR) are detailed in the following table.