TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
CARRY OUT 3D CHECKS.
A. Isolate the high voltage capacitor from the circuit.
B. Continuity check must be carried out with measuring instrument which is set to the highest
B. Continuity check must be carried out with measuring instrument which is set to the highest
resistance range.
C. A normal capacitor shows continuity for a short time (kick) and then a resistance of about 10M
Ω
after it has been charged.
D. A short-circuited capacitor shows continuity all the time.
E. An open capacitor constantly shows a resistance about 10 M
E. An open capacitor constantly shows a resistance about 10 M
Ω
because of its internal 10M
Ω
resistance.
F. When the internal wire is opened in the high voltage capacitor shows an infinite resistance.
G. The resistance across all the terminals and the chassis must be infinite when the capacitor is
G. The resistance across all the terminals and the chassis must be infinite when the capacitor is
normal.
If incorrect reading are obtained, the high voltage capacitor must be replaced.
CARRY OUT 4R CHECKS.
D
HIGH VOLTAGE CAPACITOR TEST
E
SWITCH TEST
CARRY OUT 3D CHECKS.
Isolate the switch to be tested and using an ohmmeter check between the terminals as described in
the following table.
Isolate the switch to be tested and using an ohmmeter check between the terminals as described in
the following table.
Table: Terminal Connection of Switch
Plunger Operation
COM to NO
COM to NC
Released
Open circuit
Short circuit
Depressed
Short circuit
Open circuit
COM; Common terminal,
NO;
NO;
Normally open terminal
NC;
Normally close terminal
If incorrect readings are obtained, make the necessary switch adjustment or replace the switch.
CARRY OUT 4R CHECKS.
CARRY OUT 3D CHECKS.
If the fuses M8A are blown, there could be shorts in the high voltage transformers (1) and/or (2) or there
is a ground in wire harness. Check and/ or replace the high voltage transformers(1) and/or (2) or repair
the wire harness.
is a ground in wire harness. Check and/ or replace the high voltage transformers(1) and/or (2) or repair
the wire harness.
CARRY OUT 4R CHECKS.
CAUTION: Only replace
fuses M8A
with the correct value replacement.
F
FUSES M8A TEST
G
FUSE F13A TEST
CARRY OUT 3D CHECKS.
If the fuse F13A is blown, there could be a shorts or grounds in electrical parts or wire harness.
Check them and replace the defective parts or repair the wire harness.
Check them and replace the defective parts or repair the wire harness.
CARRY OUT 4R CHECKS.
CAUTION: Only replace fuse F13A with the correct value replacement.
H
FUSE F6.3A TEST
CARRY OUT 3D CHECKS.
If the fuse F6.3A is blown when the door is opened, check the 1st. latch switch, monitor switch and
monitor resistor.
If the fuse F6.3A is blown by incorrect door switching replace the defective switch(s) and the fuse
F6.3A.
monitor resistor.
If the fuse F6.3A is blown by incorrect door switching replace the defective switch(s) and the fuse
F6.3A.
CARRY OUT 4R CHECKS.
CAUTION: Only replace fuse F6.3A with the correct value replacement.