23
1. CARRY OUT 3D CHECKS.
2. Remove the control panel assembly referring to "CON-
TROL PANEL ASSEMBLY REMOVAL".
3. Disconnect the leads from all switches.
4. Remove the two (2) screws holding the latch hook to
the oven cavity.
5. Remove the latch hook.
6. Push the retaining tab outward slightly and remove the
switch.
Re-install
1. Re-install each switch in its place. The 2nd. interlock
relay control switch and the latch switch are in the lower
position and the 1st. interlock switch is in the upper
position. The monitor switch is in the middle position.
2. Re-connect wire leads to each switch.
Refer to pictorial diagram.
3. Secure latch hook (with two (2) mounting screws) to
oven flange.
1ST. INTERLOCK SWITCH, LATCH SWITCH, 2ND. INTERLOCK RELAY CONTROL SWITCH,
AND MONITOR SWITCH REMOVAL
If the 1st. interlock switch, latch switch, 2nd. interlock relay
control switch and monitor switch do not operate properly
due to a mis-adjustment, the following adjustment should
be made.
1. CARRY OUT 3D CHECKS.
2. Loosen the two (2) screws holding the latch hook to the
oven cavity front flange.
3. With door closed, adjust latch hook by moving it back
and forth, and up and down. In and out play of the door
allowed by the upper and lower position of the latch
hook should be less than 0.5mm. The vertical position
of the latch hook should be adjusted so that the 1st.
interlock switch, latch switch and 2nd. interlock relay
control switch  are activated with the door closed. The
horizontal position of the latch hook should be adjusted
so that the plunger of the monitor switch is pressed with
the door closed.
4. Secure the screws with washers firmly.
5. Check the operation of all switches. If each switch has
not activated with the door closed, loosen screw and
adjust the latch hook position.
After adjustment, check the following.
1. In and out play of door remains less than 0.5mm when
in the latched position. First check upper position of
latch hook, pushing and pulling upper portion of door
toward the oven face. Then check lower portion of the
latch hook, pushing and pulling lower portion of the
4. Make sure that the monitor switch is operating properly
and check continuity of the monitor circuit.    Refer to
chapter "Test Procedure" and Adjustment procedure.
Figure C-4. Switches
1ST. INTERLOCK SWITCH, LATCH SWITCH, 2ND. INTERLOCK RELAY CONTROL SWITCH,
AND MONITOR SWITCH ADJUSTMENT
door toward the oven face. Both results (play in the
door) should be less than 0.5mm.
2. The 1st. interlock switch, latch switch and 2nd. inter-
lock relay control switch interrupt the circuit before the
door can be opened.
3. Monitor switch contacts close when door is opened.
4. Re-install outer case and check for microwave leakage
around door with an approved microwave survey meter.
(Refer to Microwave Measurement Procedure.)
Figure C-5. Latch Switch Adjustments
Latch Hook
Tabs
Tab
Tab
Tab
Tab
Monitor Switch
Latch Switch
(Cabinet side)
1st. Interlock Switch
2nd. Interlock Relay 
Control Switch (Oven side)
Latch Hook
Latch Switch
Lever A
Latch Switch
Lever B
Latch Switch
Lever C
Latch Head
Latch Head
Handle
Lever
Door
Handle
Latch
Lever
Monitor
Switch
1st. Interlock Switch
2nd. Interlock Relay 
Control Switch
Latch Switch
CHOKE COVER
1. Disconnect the oven from the power supply.
2. Open the oven door and wedge it open.
3. Insert a putty knife (thickness of about 0.5mm) into the
DOOR PARTS REPLACEMENT
gap between the choke cover and door frame as shown
in Figure C-6 to free engaging parts.
4. Pry the choke cover by inserting a putty knife as shown
in Figure C-6.