TEST PROCEDURES
COMPONENT TEST
PROCEDURES TO BE TAKEN WHEN THE FOIL PATTERN ON THE PRINTED WIRING BOARD (PWB) IS OPEN.
To protect the electronic circuits, this model is provided with a fine foil pattern added to the input circuit on the PWB, this foil
pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide given below for repair.
Problem: POWER ON, indicator does not light up.
CARRY OUT 3D CHECKS.
STEPS
OCCURRENCE
CAUSE OR CORRECTION
1
The rated AC voltage is not present at
Check supply voltage and oven power cord.
Power terminal of CPU connector (CN-A).
2
The rated AC voltage is present at primary
Low voltage transformer or secondary circuit defective.
side of low voltage transformer.
Check and repair.
3
Only pattern at "a" is broken.
*Insert jumper wire J1 and solder.
(CARRY OUT 3D CHECKS BEFORE REPAIR)
4
Pattern at "a" and "b" are broken.
*Insert the coil RCILF2003YAZZ between "c" and "d".
(CARRY OUT 3D CHECKS BEFORE REPAIR)
NOTE: *At the time of these repairs, make a
visual inspection of the varistor for burn-
ing damage and examine the transformer
with tester for the presence of layer short
circuit (check primary coil resistance).
If any abnormal condition is detected,
replace the defective parts.
CARRY OUT 4R CHECKS.
(J1)
a
b
c
d
VRS1
CN - A
S
P
15
Page of 23