R-209 - Sharp Home Appliance Service Manual (repair manual). Page 8

Read Sharp R-209 Service Manual online

R-209(SL)
R-209(W)
6
CK = Check / RE = Replace
MAGNETRON
HIGH VOLTAGE TRANSFORMER
H.V. RECTIFIER ASSEMBLY
HIGH VOLTAGE WIRE
HIGH VOLTAGE CAPACITOR
MONITORED LATCH SWITCH 
LATCH
 SWITCH 
MONITOR SWITCH 
TEMPERATURE FUSE 
TIMER MOTOR
TIMER SWITCH
FAN MOTOR
TURNTABLE MOTOR
FUSE T6.3A
CONTROL UNIT
RELAY (RY-1)
FOIL PATERN ON P.W.B.
POWER SUPPLY CORD
SHORTED WIRE HARNESS
OPENED WIRE HARNESS
OVEN LAMP
WALL OUTLET
MISADJUSTMENT SWITCH
HOME FUSE OR BREAKER
BLOCKED COOLING FAN
BLOCKED VENTILATION
NOISE FILTER
H.V. FUSE
Home fuse blows when power
supply cord is plugged into
wall outlet.
FUSE T6.3A blows when
power supply cord is plugged
into wall outlet.
Oven does not start when the
timer is set.
Oven lamp does not light
(Other function is normal.)
Fan motor does not operate.
(Other function is normal.)
Turntable motor does not op-
erate. (Other function is nor-
mal.)
Oven or any electrical parts
does not stop.
Oven seems to be operating
but little or no heat is produced
in oven load. (Microwave
power level is set at HIGH.)
Oven does not seems to be
operating properly when MED
HIGH, MED, MED LOW or
LOW is set. (Oven operates
properly at HIGH.)
Oven goes into cook cycle but
shuts down before end of cook-
ing cycle.
OFF
CONDITION
PROBLEM
CONDITION
POSSIBLE CAUSE
AND
DEFECTIVE PARTS
TEST PROCEDURE
ON
CONDITION
A B C
CK
D E E E     F K   K   I   I   G   L M N
RE CKCKRECK CKCKCK CK
H J
TROUBLESHOOTING GUIDE
When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks.
Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure
letter which will be found in the “Test Procedure” section.
IMPORTANT: If the oven becomes inoperative because of a blown fuse  T6.3A in the monitored latch switch  - timer
switch  - monitor switch circuit, check the monitored latch switch , timer switch and monitor switch  before
replacing the fuse  T6.3A.
Page of 32