Read Sharp R-201 Specification online
R-201M - 3
WARNING
Servicing and repair work must be carried out only by
trained service engineers.
trained service engineers.
The parts marked '*' on the parts list and schematic
diagram have voltages in excess of 250V.
diagram have voltages in excess of 250V.
Removal of the outer wrap gives access to potential
above 250V.
above 250V.
All the parts marked "
∆
" on the parts list may cause
undue microwave exposure, by themselves, or when
they are damaged, loosened or removed.
they are damaged, loosened or removed.
CAUTION
MICROWAVE RADIATION
Do not become exposed to radiation from the
magnetron or other parts conducting microwave en-
ergy. All input and output microwave connections,
waveguides, flanges and gaskets must be secured.
Never operate the device without a microwave en-
ergy absorbing load attached. Never look into an
open waveguide or antenna while the device is ener-
gized.
magnetron or other parts conducting microwave en-
ergy. All input and output microwave connections,
waveguides, flanges and gaskets must be secured.
Never operate the device without a microwave en-
ergy absorbing load attached. Never look into an
open waveguide or antenna while the device is ener-
gized.
SPECIFICATION
Power Requirements
230 -240 Volts 50 Hertz Single phase, 3 wire grounded
Power Consumption
1.24KW
Power Output
800 watts nominal of RF microwave energy (measured by way of IEC 705)
Operating frequency of 2450 MHz
Operating frequency of 2450 MHz
Case Dimensions
Width 449 mm Height 282 mm including foot Depth 385 mm
Cooking Cavity Dimensions
Width 287 mm Height 220 mm Depth 311 mm
Turntable diameter
272 mm
Control Complement
Mechanical Control System
Microwave Power for Variable Cooking
Repetition Rate :
HIGH .................... Full power throughout the cooking time
MEDIUM HIGH ..... approx. 70% of Full Power
MEDIUM ............... approx. 50% of Full Power
MEDIUM LOW ..... approx. 30% of Full Power
LOW ..................... approx. 10% of Full Power
Set Weight
Approx. 13.3 kg
PRODUCT DESCRIPTION
WARNING
THIS APPLIANCE MUST BE EARTHED
. THE WIRES IN THIS MAINS LEAD ARE COLOURED IN
ACCORDANCE WITH THE FOLLOWING CODE:
GREEN-AND-YELLOW : EARTH BLUE : NEUTRAL BROWN : LIVE
GREEN-AND-YELLOW : EARTH BLUE : NEUTRAL BROWN : LIVE
If the mains lead is replaced, only part number QACCBA030WRE4 should be used
CAUTION / WARNING
As part of our policy of continuous improvement, we reserve the right to
alter design and specifications without notice
alter design and specifications without notice
Display