UP-X500 (serv.man3). Wall Mount Bracket Manual - Sharp EPOS Service Manual (repair manual). Page 2

Read Sharp UP-X500 (serv.man3) Service Manual online

UP-W01MK   
– 2 –
1. INSTALLING THE DISPLAY PLATE
1.
When Diaplay plate 
1 is fixed, standard <1> < 2> should closely to
“LCD UNIT” .
2.
Screw 
2 should be fixed into 3 holes of display plate 1.
Caution: When fixed by screw, it should be fixed after confirming
whether standard part adhered colsely or not.
2. INSTALLING THE SET PLATE
1. Eathernet cable should be connected to “SET”.
(Only Eathernet cable is used)
2. Spring 
1 should be fixed to set plate 3 by screw 2.
3. It should make a holes on 
a, b, c, d, to put set plate 3 in place.
(
b, c, d is removing a rubber foot.)
4. Put set plate 
3 upon “SET” and then be fixed by screw 4.
5. Both set plate 
3 and display plate 6 should be fixed by screw 5.
3. INSTALLING THE BASE PLATE
1. It should be horizontally fixed be screw 
1 on the position to put set
in place.
Caution: When fixed by screw 
1, horizontal space : 71mm
Space screw 
1 head and wall : 2mm over.
2. The hole of part 
a should be temporarily fixed to screw 1.
SET
1
2
2
1
A
A
A
A
Standard 
< 2 >
Standar
< 1 >
LCD UNIT
A
SET
1
3
2
4
4
5
b
c
d
5
6
a
Eathernet cable
AC cord
Eathernet cable
SET
71mm
2mm
WALL
1
1
a
 
Page of 4
Display