3) Buzzer
Set up duration and frequency for the test of buzzer equipped to board.
In case that user set up the buzzer to be operated continuously, the buzzer
will ring a sound just less than 10 seconds even though the buzzer is
supposed to ring more than 10 seconds in setup.
[Figure 8] Buzzer Environment Setup
Default
Simple buzzer sound will be ringed when buzzer is operated normally.
Custom
- Duration (1~254) : This is the time for buzzer to ring.
Duration can be entered with the value from 1 to 254, and the buzzer
sound rings based on the ranges from minimum 0.05Sec to maximum
12.7Sec with 50Msec per unit.
- Frequency (1~255) : This is the frequency band that buzzer can ring.
Frequency can be entered with the value from 1 to 255, and its value
can be expressed from minimum value 100Hz to maximum value