UP-V5500 (serv.man18). UPV-5500 POS TEST User Guide 1.0.3 - Sharp EPOS Driver / Update. Page 14

Read Sharp UP-V5500 (serv.man18) Driver / Update online

Valcretec POS Test User Guide 
 
11 
 
 
 
3)  Buzzer 
Set up duration and frequency for the test of buzzer equipped to board.   
In case that user set up the buzzer to be operated continuously, the buzzer 
will  ring  a  sound  just  less  than  10  seconds  even  though  the  buzzer  is 
supposed to ring more than 10 seconds in setup.   
 
 
[Figure 8] Buzzer Environment Setup 
 
   Default 
Simple buzzer sound will be ringed when buzzer is operated normally.   
 
   Custom 
- Duration (1~254) : This is the time for buzzer to ring.   
Duration can be entered with the value from 1 to 254, and the buzzer 
sound rings based on the ranges from minimum 0.05Sec to maximum 
12.7Sec with 50Msec per unit.   
- Frequency (1~255) : This is the frequency band that buzzer can ring. 
Frequency can be entered with the value from 1 to 255, and its value 
can  be  expressed  from  minimum  value  100Hz  to  maximum  value 
Page of 28