UP-5700 (serv.man15). UP5700-001 Cabinet changes for better Servicability - Sharp EPOS Technical Bulletin (repair manual). Page 6

Read Sharp UP-5700 (serv.man15) Technical Bulletin online

Figure-4
6/7
Old
Bending of the main PWB sometimes occurs when
connecting the ISA PWB to the main PWB due to
pressure being exerted in the direction of the arrow
as shown in the figure above. The bending of the
main PWB can result in faulty connections.
SECT a-a
Connector
Main PWB
ISA PWB
Bottom cabinet
Main PWB
New
Connector
ISA PWB
Added rib
Bottom cabinet
SECT a-a