UP-5300 (serv.man2). UP5300 Internal Printer (UPT80BP) Service Manual - Sharp EPOS Service Manual (repair manual). Page 14

Read Sharp UP-5300 (serv.man2) Service Manual online

No.
COMMAND
FUNCTION
CODE
15
ESC - n
Select/cancel underline
<1Bh><2Dh> n
[Range]
à
 n 
à
 2
48 
à
 n 
à
 50
[Function] 
Selects or cancels the underline. 
When n=0 or 48, the underline is canceled. 
When n=1 or 49, the 2-dot-wide underline is selected. 
When n=2 or 50, the 3-dot-wide underline is selected. 
[Notes] 
No underline is provided in the following cases. 
1) Laterally-turned character 
2) Blank portions specified by set absolute position/set relative
position 
The same processing as “select/cancel underline” using ESC ! is
performed. 
[Default] 
n = 0 
[Reference] 
ESC ! 
No.
COMMAND
FUNCTION
CODE
16
ESC 2
Set 30/203 inch line feed
amount
<1Bh><32h> 
[Function]
Sets the distance for one line feed to 30/203 inch. 
The line spacing is 6 dots.
Caution
In case of double-height, the line spacing is 0 dots. 
If the line spacing is less than 6 dots, 
printing may be disturbed when printing is started
from the printer stop state. 
In this case, printing must be made with the printer
in the operating state 
(continuous printing from the previous line).
[Reference]
ESC 3: Set line feed amount 
No.
COMMAND
FUNCTION
CODE
17
ESC 3 n
Set line feed amount
<1Bh><33h>
[Range]
à
 n 
à
 255
[Function]
Sets the distance for one line feed to [n 
×
(basic calculation pitch)]
inch. 
Caution
If the line spacing is less than 6 dots, 
printing may be disturbed 
when printing is started from the printer stop state.
In this case, printing must be made with the printer
in the operating state 
(continuous printing from the previous line). 
[Default]
n = 30 (30/203 inch) 
[Reference] 
ESC 2: Set 30/203 inch line feed amount 
No.
COMMAND
FUNCTION
CODE
18
ESC 4 n [DATA]
(72xn)
Set logo stamp
<1Bh><34h> n ...
[Range]
à
 n 
à
 240: Number of dots in vertical direction 
[Function] 
Sets the logo stamp. 
Setting is made with side slice. 
Stamp setting of MAX 30 mm in vertical size is possible. 
UP-T80BP has 2 stamp data area, and can set or print each of them.
In this command, data is set for stamp No. 0.
This command acts same as following command;
ESC 6 <00h> n ...
[Notes]
In printing the logo between the print position and cut position, verti-
cal size of 14.5 mm can be used.
This size can be set by using n = 108.
6-dot feed is performed before the logo stamp data is printed. 
[Default]
n = 160 (30/203 inch) 
DATA = Default stamp data
[Reference]
ESC 6 m n: Set logo stamp (select stamp No.)
ESC o: Print logo stamp 
GS o m: Print logo stamp (select stamp No.)
[Notice]
The UP-T80BP can not receive data while writing the logo stamp data
in internal memory.
The UP-T80BP inform it to host by sending XOFF character or turn-
ing off DTR signal.
When you turn off the UP-T80BP or execute a Master Reset,this data
remains.
When this command execute, the image setting data is cleared.
No.
COMMAND
FUNCTION
CODE
19
ESC 6 m n
[DATA] (72xn)
Set logo stamp
<1Bh><36h> m n ...
[Range]
à
 m 
à
 1: Setting stamp No.
à
 n 
à
 240: Number of dots in vertical direction
[Function]
Sets the logo stamp.
Setting is made with side slice.
Stamp setting of MAX 30 mm in vertical size is possible.
UP-T80BP has 2 stamp data area, and can set or print each of them.
Select stamp No. by "m".
[Notes]
In printing the logo between the print position and cut position, verti-
cal size of 14.5 mm can be used.
This size can be set by using n=108.
6-dot  feed is performed before the logo stamp data is printed.
4 – 7
Page of 74
Display