UP-3515 (serv.man13). UP-3500 UP-3515 Enhancement Version 1.52 Programming and Operation Manual and revision history - Sharp EPOS Driver / Update

up-3515 (serv.man13) driver / update
Model
UP-3515 (serv.man13)
Pages
6
Size
1.15 MB
Type
PDF
Document
Driver / Update
Brand
Device
EPOS / UP-3500 UP-3515 Enhancement Version 1.52 Programming and Operation Manual and revision history
File
up-3515-sm13.pdf
Date

Read Sharp UP-3515 (serv.man13) Driver / Update online

Page 1 - 6 
 
 
 
 
 
 
 
 
 
 
UP3500/3515 
 
Enhancement Version 
 
Programming and Operation 
Manual 
 
ROM Version V1.52 
(based on V1.51) 
 
 
 
 
 
 
SHARP Electronics (Europe) GmbH 
December 2012 
Rev. 01 
 
 
Page 2 - 6 
1.
 
>>> CHANGES / IMPROVEMENTS / CORRECTIONS <<<....................................................................................3
 
2.
 
WRONG CALCULATION IN CASE OF ITEMDISCOUNT. ............................................................................................3
 
3.
 
WRONG KP PRINT AFTER ITEM VOID IN RELATION TO SIDEABLE/CONDIMENT REGISTRATION..............................3
 
4.
 
MISSING ITEMS BY DOWNLOAD OF CUSTOMER SALES REPORT WITH ONLINE FUNCTION. ..................................3
 
5.
 
DRAWER ALARM DOES NOT WORK AT THE SATELLITE. ..........................................................................................3
 
6.
 
PRINTING OF TAX EVEN THE TAX AMOUNT IS 0. .....................................................................................................3
 
7.
 
CALCULATION METHOD IN CASE OF GRANTING MIXED PROMOTION, E.G. MIX&MATCH AND SBTL%..............3
 
8.
 
ERROR “LACKING MEMORY” OCCUR DURING A CLERK SIGNON..........................................................................3
 
9.
 
REGISTRATION OF DIFFERENT PLUTYPE COMBINATIONS TOGETHER WITH SIDEABLEPLU. ..................................4
 
10.
 
BILL SEPARATION IN COMBINATION WITH ITEM SPLIT.............................................................................................4
 
11.
 
CCD ERROR AT TIMEOUT OF EMPLOYEE.................................................................................................................5
 
12.
 
SECURED REPORTS. ...................................................................................................................................................5
 
13.
 
SECURED REPORTS IN INLINESYSTEM. .....................................................................................................................5
 
14.
 
SECURED REPORTS WITH A FOLDER NAME LENGTH OF 8 CHARACTERS. ..............................................................5
 
15.
 
ONLINE FUNCTION (CLERK ZREPORT) IN RELATION TO THE ECR STATUS. .............................................................6
 
16.
 
LEAVING THE DIAGNOSTIC MODE MAY RESULT IN AN ERROR. ..............................................................................6
 
17.
 
STACKED REPORTS. ...................................................................................................................................................6
 
 
 
Page 3 - 6 
Important note:
 
 
The ROM version V1.52 is based on V1.51, but it is not compatible (neither Data nor Language Text 
Resources) with this ROM version. 
 
 
1. 
   
 
>>> Changes / Improvements / Corrections <<<
 
 
 
2. 
Wrong calculation in case of ItemDiscount. 
If an ItemDiscount has been granted, it could happen that the discount was calculated from the 
Subtotal, but not from that Item for which the discount has been given for. This has been 
corrected. 
 
 
3. 
Wrong KP print after Item Void in relation to Sideable/Condiment registration. 
In case of an Indirect Item Void after a mixed registration with Sideable, Condiment and Tied 
Condiment PLU’s, the KP print of the articles were not correct. With this version, the print out is 
correct. 
 
 
4. 
Missing Items by download of Customer Sales Report with Online function. 
After the Customer Sales Report has been cleared either by OnlineRJE or by 
\3 X2/Z2 MODE\2 RESETTING\13 CUSTOMER SALES 2 some new registrations have been charged 
to one/several Customer(s). At the previous ROM Version, it could happen, that by reading the 
CUSTOMER SALES report by Online RJE the registered items are missing. This has been corrected. 
 
 
5. 
Drawer alarm does not work at the Satellite. 
If the SRV parameter #990A (open drawer at TimeOut of last Employee) is set to YES, a set drawer 
alarm will not occur at the Satellite. This has been corrected. 
 
 
6. 
Printing of TAX even the TAX amount is 0. 
If by SRV #905B the ‘TAX printing when TAX is 0’ is set to PRINT, the TAX amount were not printed 
by mistake. This is corrected. 
 
 
7. 
Calculation method in case of granting mixed promotion, e.g. Mix&Match and SBTL%. 
In case of granting mixed promotion, the SBTL% promotion discount was calculated from the gross 
amount. By this version, the SBTL% promotion discount will be calculated from the already by the 
Mix&Match discount reduced amount. This conforms to the specification of Version 1.50. 
 
 
8. 
Error “LACKING MEMORY” occur during a Clerk SignOn. 
If a Clerk tries to make a SignOn at a Satellite while there is an active online communication via the 
RS232 port of the Master with a PC, the error “LACKING MEMORY” may occur. At this version, 
the SignOn at the Satellite will not result in an error, even there is an active online communication 
between the Master and a PC. 
 
 
Page 4 - 6 
9. 
Registration of different PLUType combinations together with SideablePLU. 
With ROM Version V1.30 the SIDEABLE PLU type has been introduced. Even the registration of 
SIDEABLE PLU’s in combination with other types of PLU (e.g. LINK, COMBO, CONDIMENT) underlay 
to certain restrictions, they were possible sometimes. This could result in wrong print out of the 
registration. In the following, we summarize such restrictions and add the new ones which are 
introduced with this new ROM Version. 
 
 Neither a “SIDE” nor a “SIDE W.ROLLUP” PLU can be registered individually. They are belonging 
to a “SIDEABLE” PLU, but it is possible to assign them to a Link or Combo PLU. In such kind of 
registration, they will be treated as normal articles. 
 
 Even a “SIDEABLE” PLU can be part of a Condiment, Link or Combo PLU, they will be registered 
as a normal article. It will loose its SIDEABLE property. It is neither possible to register a “SIDE” nor 
a “SIDE W.ROLLUP” after such a registration. 
 
 After the registration of a “SIDEABLE” PLU, up to 30 SIDE PLU types/Free Texts which should 
belong to this leading PLU can be registered. 
 
 A registration of a “SIDE” or a “SIDE W.ROLLUP” PLU after a SIDEABLE PLU registration which is a 
CondimentTied is not possible. 
 
 A Sideable PLU may have a Condiment Link. 
Following registration is possible: 
 Sideable PLU with Condiment Link 
 Condiment Tied(s) 
 Side(s) or SideRU(s) 
If the Sideable PLU will be voided, all of the Condiment Tied(s), Side(s) and SideRU(s) will be voided 
as well. 
 
 The Sideable PLU with all of its Side(s)/SideRU(s) must belong to the same PLU Group (SortGroup). 
 
 A CondimentTied can be a Sideable, but if such a Condiment Tied is registered, it will loose its 
Sideable property. 
 
 Side/SideRU must not be a LeadingCondiment (must not have a Condiment Link). 
 
 Side/SideRU must not be a CondimentTied. 
 
 Side/SideRU must not be a LeadingLink or LeadingCombo PLU. 
 
 A LinkTied or ComboTied should not be a Sideable, Side or SideRU. If such a Tied is registered, it 
will loose its Side property. 
 
 
10. 
Bill Separation in combination with item split. 
If an item is split during the Bill Separation operation (a bottle of wine for two people), it was 
possible that a zero amount for the split items were transferred to the target GLU. With this 
version, the correct amount for the items will be split. 
 
 
Page of 6
Display

Download Sharp UP-3515 (serv.man13) Driver / Update

Here you can read online and download Sharp UP-3515 (serv.man13) Driver / Update in PDF. UP-3515 (serv.man13) driver / update will guide through the process and help you recover, restore, fix, disassemble and repair Sharp UP-3515 (serv.man13) EPOS. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.