15.
 
Screen limitation [V1.65] 
For each Clerk a screen limitation can be set in order to disable the access to certain screens. This is 
current specification. But in case no clerk is signed on, every screen can be displayed without any 
limitation. 
To make it possible, to have a screen which can be shown only to signed-on clerks a new SRV 
parameter (SRV #992D) has been introduced. If this SRV parameter is set the screen# 30 can only 
be opened if a clerk is signed on and has no limitation.  
If the clerk is signed on, the above mentioned screen limitation setting becomes valid. 
 
Contactless Clerk Key for 
Employee Time In/Out 
 
Display screen #30 only if 
a clerk is signed on. 
#992-C 
Default 
No 
 
No 
 
Yes 
 
 
No 
 
Yes 
 
Yes 
 
No 
 
Yes 
 
 
No 
 
Yes 
 
 
16.
 
Customer charge limit [V1.65] 
Currently the Customer charge limit will be validated by every single item registration. Even if the 
Customer wants to pay by Cash, it can happen that the registration is not possible because it 
exceeds the set Customer limit. 
If the already existing SRV parameter #986A is set to -4 (Customer code entry finalized by -> Any 
Payment) the Customer limit will be validated only at the end of the transaction by using CHARGE. 
 
17.
 
Sending of registration data to the Ethernet network [V1.67] 
In order to use a PC as e.g. a customer display or as a video surveillance system (with corresponding 
software) it is possible to send out registration data over the Ethernet network. During a 
registration, every single item registration will be send. After finalizing the registration, the total 
amount as well as the clerk name and number will be sent additionally. 
To activate this feature the new Service parameter #997 has to be set accordingly. With this 
parameter the last octet of the IP address of the Server PC as well as the port the Server PC is 
listening to must be defined. 
 
Listening Port of Server PC 
Port &HFEED + X 
Last octet of IP address of Server PC 
#997 
Default 
000 
0000 
 
 
Prior to set the corresponding SRV parameter, a proper working Inline System has to be setup. Also 
the MWS at \6 PGM2 MODE\2 SETTING\23 MWS CONFIG\[IP ADDRESS1-4] must set to the same 
network. After setting this SRV parameter #997 a Service Reset is necessary. 
For transmitting the data, the UDP protocol will be used, means the ECR does not expect any 
answer from the Server PC. 