UP-3500 (serv.man21). UP-3500 Enhancement Version 1.44 Programming and Operation Manual and revision history - Sharp EPOS Service Manual (repair manual). Page 9

Read Sharp UP-3500 (serv.man21) Service Manual online

 
 
Page 9  14 
6.
 
Improvement of the SCM(+) / SCM() function. 
With the existing SRV parameter #907A, SCM input can be set to compulsory. 
In case this parameter is set i.e. to 6 (compulsory for all Clerks) one Clerk has to make the SCM 
input in order to perform the SCM entry for all Clerks. 
In previous versions, in case of SCM(2), the ECR is comparing the SCM(2) amount against the 
individual Clerk totalizer of that Clerk who wants to make the SCM(2). If the Clerk who wants to 
make the SCM(2) differs from that Clerk who makes the SCM(+), it is possible to make a SCM(2) of 
only that amount which is less or equal to the turnover of the Clerk. In this case, the previous 
entered SCM(+) amount by the other Clerk is disregarded. This has been changed at this version. 
 
If SRV parameter #907A is set to +1 (1 or 5), the ECR compares the SCM(2) amount against the 
individual Clerk totalizer. This is like in the previous version. 
 
If SRV parameter #907A is set to +2 (2 or 6), the ECR compares the SCM(2) amount against the 
CA/CHK ID totalizer of the terminal. This has been changed compared to the previous version. 
 
If SRV parameter #907A is set to 0 or 4 (SCM input is not compulsory), the new below SRV 
parameter #991A will be considered. 
 
If SRV parameter #991A is set to +4, the ECR compares the SCM(2) amount against the CA/CHK ID 
totalizer. 
 
If SRV parameter #991A is set to 0, the ECR compares the SCM(2) amount against the individual 
Clerk totalizer. 
Because of the additional checking of the new SRV parameter, it is possible to set up the ECR like 
with the previous ROM version. 
 
 
Checking of SCM(2) amount 
(only if 907A=0 or 4) 
GLU key status 
after Media & Bill 
9912A  Default 
Setting 1 
√ 
Setting 2 
 
against individual Clerk 
totalizer 
Setting 3 
 
Setting 1 
 
Setting 2 
 
against 
CA/CHK ID totalizer 
Setting 3 
 
 
 
Entry of SCM after registration 
SCM compulsory 
9072A  Default 
non compulsory (refer #991A) 
√ 
for individual Clerk (Cashier) 
 
disable 
for all Clerks (Cashiers) 
 
non compulsory (refer #991A) 
 
for individual Clerk (Cashier) 
 
enable 
for all Clerks (Cashiers) 
 
 
Page of 14
Display