1. General
This diagnostics program is used for simplified check of the ER-
A850/A880 operations in the board test, the process test and servic-
ing. It is composed of three programs as shown below.
The board test diagnostics is supplied as the test ROM. The process
test diagnostics is built in the system ROM. The service-man diagnos-
tics is supplied in a floppy disk as an execution object. The programs
are loaded from the PC to the ER-A850/A880 by using the application
program loader (hereinafter referred to as "APLD") program. All diag-
nostics programs are executed by supplying a command with the AT
key after initiating the MS-DOS. 
2. System Configuration
2-1. Service Test System
Connect the ER-A850/A880 body and the PC with an RS-232C cross
cable. Connect the ER-A850/A880 with the AT key board. For con-
nection between the ER-A850/A880 and the PC, refer to the Opera-
tion Manual of the ER-A850/A880 application program loader.
Fig. 2.1 Service test connection
2-2. Board Test System
ER-A850/A880 body
6-pin small DIN type AT keyboard
Test ROM (The test ROM is inserted to the system Rom position
on the main PWB.)
Fig. 2-2 Board test connection
2-3. Process Test System
ER-A850/A880 body
6-pin small DIN type AT keyboard
Fig. 2-3 Process test connection
3. Service-man Diagnostics
3-1. Loading Diagnostics
Set the ER-A850/A880 DIP switch as shown in Fig. 3-1, and supply
power to the ER-A850/A880. Use APLD to load the service-man diag-
nostics  after saving data in the RAM disk. For loading and saving
data, refer to the operation manual of the ER-A850/A880 application
program loader.
Fig. 3-1 DIP switch setting for loading diagnostics program
Note: 
Before operating the system switch, be sure to turn off the
power. 
Before executing the service-man diagnostics, be sure to
save date in the RAM disk. If not, the data may be de-
stroyed. 
To load the service-man diagnostics, RAM disk area of min.
25KByte is required. 
3-2. Execution of Diagnostics
Set the ER-A850/A880 DIP switch as shown in Fig. 3-2, and supply
power to the ER-A850/A880.
Fig. 3-2 DIP switch setting for executing diagnostic program
After initiating the MS-DOS, execute "SRV.EXE" by entering as fol-
lows with the AT key:
 C>SRV
"C>" is the DOS prompt. 
The diagnostics program is initiated to display the menu screen as
shown below. The highlighted cursor is moved with the cursor up key
(
) and the cursor down key (
) of the AT key. Move the cursor to the
diagnostics item to be executed, then press the Enter key, and the
selected individual diagnostics program will be executed. After com-
pletion of an individual diagnostics program, the display returns to the
menu screen. To exit from the diagnostics mode, press the Esc key,
and the display will return to the DOS prompt.
PC
ER-A850/A880
RS-232C
AT key
The AT key connector of
the ER-A850/A880is of
16-pin small DIN type.
AT key
ER-A850/A880
(Built-in test ROM)
The test ROM is inserted
for test instead of the
system ROM.
AT key
ER-A850/A880
SW1
ON
OFF
OFF
OFF
OFF
ON
SW2
SW3
SW4
SW1
ON
OFF
OFF
OFF
OFF
SW2
SW3
SW4
OFF