ER-A771 (serv.man4). Programming Manual - Sharp EPOS Service Manual (repair manual). Page 49

Read Sharp ER-A771 (serv.man4) Service Manual online

ER-A771VPM
SRV MODE PROGRAMMING (“IRC SETTING”)
5 – 1
CHAPTER 5. SRV MODE PROGRAMMING (“IRC SETTING”)
Before trying to perform inline setup, make sure to create (or delete) the
files required by the inline system using the following procedure: [SRV
MODE] - [2 SETTING] - [10 FILE]. And then perform inline setup.
DISPLAY: SRV mode screen
Select "3 IRC SETTING" and press the ENTER key.
DISPLAY: IRC SETTING item selection screen
Select the item and press the ENTER key.
The item setting input screen is displayed.
1. [1 TERMINAL SETTING]
DISPLAY: Setting item select screen
Select the item to be changed and press the ENTER key.
The contents of setting are shown in the table below.
[1 SATELLITE]
DISPLAY: Setting screen
Select the item to be changed and press the ENTER key.
The setting content is described below.
When all the machine are set, press the [TL] key.
The [IRC SET UP] screen appears to start the setup.
DISPLAY: 
~
~
DISPLAY TEXT
CONTENTS
SELECT ITEM
MRS
IP ADDRESS 1
IP ADDRESS 1
000~254
192
IP ADDRESS 2
IP ADDRESS 2
000~254
168
IP ADDRESS 3
IP ADDRESS 3
000~254
000
IP ADDRESS 4
IP ADDRESS 4
000~254
000
CLERK SYSTEM
Clerk system
CENTRALIZED
INDIVIDUAL
GLU SYSTEM
GLU system
CENTRALIZED
INDIVIDUAL
D-THRU SYSTEM
Drive thru system
CENTRALIZED
INDIVIDUAL
PLU STOCK SYSTEM
PLU stock system CENTRALIZED
INDIVIDUAL
PLU SAVE FILE
PLU save file
NOT
EXIST
OTHER SAVE FILE
Other save file
NOT
EXIST
BACKUP MASTER
B a c k u p   m a s t e r
function
NOT
EXIST
IRC SET UP
1: SAVE FILE DELETE
2: OTHER FILE DELETE
3: SAVE FILE NON CREATE
4: OTHER FILE CREATE
Page of 54