b) Receive level adjustment
i)
Turn on both the receiver terminal and the transmitter terminal.
ii) Run the diagnostic program "Flag send check" on the transmitter
terminal to send a flag.
iii) Checking transmitter terminals’ output waveform
Using an oscilloscope, check the transmitter terminal’s output sig-
nal waveform.
Fig. 8 Transmitter terminal’s output waveform
(at transmitter output)
At the receiver terminal, the transmitter terminal’s output waveform
is subject to attenuation and distortion due to the length of the
trunk cable (this depends on the characteristics of the cable itself).
Fig. 9 Example of distorted signal waveform at the receiver terminal
(RG58/U 400m)
Adjust the receiver terminal adjust VR4 (20k
) on the main PWB
until the waveform as shown in Fig. 10 is obtained at IC34 (pin 1 of
the 75115). (For the location of VR4, see Fig. 6 Board location of
this subsection).
Clockwise rotation of VR4 extends the High level pulse width of
the signal at IC34 (pin 1 of the 75115).
Fig. 10 Waveform at IC34 (pin 1 of the 75115 IC in the receiver
terminal)
5) Other Checks (These Checks should be done
After the Receive Level Adjustment is
Completed).
1
 Line driver bias control circuit
Make sure that the voltage at the 
A
-side lead of the R4 resistor
(150
, 3W) shown in Fig. 6 is properly switched.
Procedure:
i)
Connect a terminating resistor or read network to the BNC con-
nector, QCNW-6856RCZZ (Fig. 2).
ii) Run the diagnostic program "Data send check", and make sure
that the voltage at point 
A
 (in Fig. 6) is switched as shown in
Fig. 11.
Fig. 11 bias circuit switching waveform
iii) If the waveform as shown in Fig. 11 is not obtained, it is most
probable that transistor Q10 (2SC4699) is defective.
2
For the other check items, refer to DIAGNOSTICS
SPECIFICATIONS
2. Battery label
The battery label is attached to the main chassis on the back surface
of the set.
The battery label has the column to show the battery replacement
date. Put down the date in the following cases:
(The battery life is about 3 years after replacement.)
When the set is installed.
When the battery is replaced after installation.
CAUTION:
When the time written below comes, ask your dealer for a
replacement of the battery.
VORSICHT:
Wenn die untenbenannte Zeit erreicht wird, ersuchen Sie bitte
Ihren Fachhändler um den Austausch der Batterie.
PRECAUTION:
Lorsque le temps écrit ci-après arrive, demander à votre
revendeur local de remplacer la batterie par une nouvelle.
ADVERTENCIA:
Cuando se alcance el tiempo indicado abajo, solicite a su
distribuidor que reemplace la batería.
Time to replace :
Austauschzeit :
Le temps de la remplacer :
Tiempo de reemplazo :
______________________
______________________
______________________
3. Precautions in installing optional RAM
PWBs
1) Background
The ER-A750 can use the ER-03MB or the ER-04MB as an optional
RAM PWB.  The ER-03MB and the ER-04MB are available in two
versions according to the difference in access time of the pseudo-
SRAM.
(1)
150 ns access time version (Not marked with "
|
"; manufactured
before June, 1996; shipped only to North America and Europe)
(2)
120 ns access time version (Marked with "
|
"); manufactured after
July, 1996 These two versions can be identified, one from the
other, by whether or not the "
|
" mark is stamped on the white
background as shown in Fig. 1 and by the marking on the case.
(See Fig. 1.)
1µ S
1µ S
3.8V
0.8V
1µ S
1µ S
12V
0V
4.3ms
17ms
3 – 2
Page of 19