5. Removing the Rear display
  1) Pull the lower cabinet pawl in the direction of 
A
 to release the
lock, and pull out the rear display in section 
B.
Fig. 4
6. Removing the Noise filter PWB,
Transformer and AC cord
  1) Removing the two screws 
1
.
  2) Remove the AC cord cover 
2
.
 3) Remove the screw 
3
 and the earth wire 
4
.
  4) Use a minus screwdriver to loosen the AC cord fixing screws (2
pcs.) of the Noise filter PWB.
  5) Pull out the AC cord 
5
 from the Noise filter PWB.
 6) Remove the screw 
7
 and earth wire 
9
.
 7) Disconnect the power supply connector 
8
 from the Transformer.
Fig. 5
7. Replacing the Noise filter PWB
and Transformer
Install the power supply unit in the reverse order of removing. Before
installing, make sure that each connector is connected securely.
*
When connecting the AC cord to the power supply unit in as-
sembly, tighten with the torque of 3 kg/cm 
±
 1 kg/cm
A
Rear display
B
Rear display
Rear display
9
4
7
3
8
5
2
1
– 2 –
Page of 12