DOS HOSPITALITY (serv.man49). UP5700-003 Not Booting problem because of bad connection - Sharp EPOS Technical Bulletin (repair manual)

dos hospitality (serv.man49) technical bulletin
Model
DOS HOSPITALITY (serv.man49)
Pages
2 Few pages! See other manuals at the bottom of the first or last page.
Size
29.04 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
EPOS / UP5700-003 Not Booting problem because of bad connection
File
dos-hospitality-sm49.pdf
Date

Read Sharp DOS HOSPITALITY (serv.man49) Technical Bulletin online

CONNECTION OF THE POWER SUPPLY TERMINAL
OF THE VCC_CORE OF THE CHIP SET.
1.Model Name:
UP-5700
2.General:
The VCC_CORE power supply terminal (K5, H25, AB19) of the chip set FireStar
(VHI82C700//-1) was not connected properly. As a measure to alleviate this problem, 
a wire was used to properly connect the terminal.
3.Phenomenon:
A mis-operation occurred in the chip set FireStar (VHI82C700//-1). As a result, the
machine failed to boot up.
4.Cause:
The VCC_CORE power supply terminal (K5, H25, AB19) of the chip set FireStar
(VHI82C700//-1) was not connected properly to the CPU PWB.
For production lots before 1998 March production, the VCC_CORE power supply
terminal was connected to a different power supply terminal in the chip set, and
therefore there were no problems.
However, in production lots after 1998 March production, there were VCC_CORE
power supply terminals mixed in the production lots which were not properly connected
to a different power supply terminal in the chip set, and as a result, cases of
disconnected VCC_CORE power supply terminals occurred.
5.Action:
Connection by wire has been carried out from 1998 March production.
For field:
For production lots until 1998 February production, the connection by wire measure
should be carried out when carrying out replacement operations on the chip set. 
It is important to note that no field action is necessary for production lots after 1998
March production.
6.Notes:
Attached supplemental documents:
Operation instructions for the changed portion of the unit.
1/2
ELECTRONIC CASH REGISTER
TECHNICAL BULLETIN
Date :
Model :
Ref :
Colour
Code :
11th January 1999
UP5700
UP5700-003
White
Sharp Electronics (UK) Ltd, Technical Support Group
Originators Initials_____________ Supervisors Initials_____________ Approval Date____________
A jumper wire should be soldered between the 
C27 “+” side solder land (FB 22 side) and the
C29 solder land (the side with the C29 silk
screened mark).
The jumper wire should be passed through the 
gap between C27 and C53 when connected.
2/2
Page of 2
Display

Download Sharp DOS HOSPITALITY (serv.man49) Technical Bulletin

Here you can read online and download Sharp DOS HOSPITALITY (serv.man49) Technical Bulletin in PDF. DOS HOSPITALITY (serv.man49) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp DOS HOSPITALITY (serv.man49) EPOS. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.