XE-A307 (serv.man2). XE-A307 Programming Manual - Sharp ECR Service Manual (repair manual). Page 3

Read Sharp XE-A307 (serv.man2) Service Manual online

XE-A207/A217/A307
MASTER RESET
– 1 –
CHAPTER 1. MASTER RESET
This programming is chiefly performed when the ECR is shipped, installed, or serviced.
1. MASTER RESET
Master resetting clears the entire memory and resumes initial values.
Initial values of language can be selected one from following 5 kinds.
• 1 English
• 2 German
• 3 French
• 4 Spanish
• 5 Swedish
Master resetting can be accomplished by using the following “Proce-
dure 1” or “Procedure 2”.
PROCEDURE 1
1) Unplug the AC cord from the wall outlet.
2) Remove 2 dry batteries and wait for 1 minute.
3) Plug in the AC cord to the wall outlet.
4) Language selection menu is displayed. Push the corresponding
number key.
5) Set current date/time and push [TL/NS] key.
6) Set tax rate and push [TL/NS] key.
7) Set mode pass code and push [TL/NS] key.
8) Set manager pass code and push [TL/NS] key.
9) Set logo message and push [TL/NS] key.
10) REG mode screen is displayed.
11) Insert 2 dry batteries.
PROCEDURE 2
1) Unplug the AC cord from the wall outlet.
2) Push [receipt paper feed] key and [CL] key.
3) Plug in the AC cord to the wall outlet during the depression of above
2 keys.
4) Language selection menu is displayed. Push the corresponding
number key.
5) Set current date/time and push [TL/NS] key.
NO BATTERY
Page of 54