Read Sharp XE-A303 (serv.man3) Service Manual online
XE-A303 (V)
PROGRAM MODE
2 – 14
5. EASY PROGRAMMING
Easy programming roughly consists of the following two types of pro-
gramming.
1. Direct key or code entry type.
2. Guidance message type on usual programming.
Reports that show the contents of individual programming can be
printed.
printed.
[PURPOSE]
It aims to be able to program easily by using the guidance messages by
the easy programming.
[OPERATION]
Perform the programming to enter the parameter according to the guid-
ance message.
The guidance message is displayed on the LCD-display every time.
It shows the information related the entry data at each step.
Each programming data and the text data is entered by using a key-
board.
board.
It is used some key as special key to enter each data at the Easy Pro-
gramming operation.
There are follows.
1. DIRECT KEY OR CODE ENTRY TYPE
<Programming method>
At PGM mode, it becomes set up mode, as it pushes a key of a direct
key or code entry that it wants to set up.
For example:
Push [DEPT1] key, if you want to set up DEPT1 items.
Push [%1] key, if you want to set up %1 item.
After that, every time it pushes [ST] key, a set up item changes with price,
text, programming ...
text, programming ...
To change a programming content, it changes it using a numeric key.
As additional way, [00] key can be used as a incremental while an indi-
cator lights on.
i.e. By pushing [00] key for a digit of parameters, a figure changes 0
3
1
3
2
3
...
The data is changed by pushing [ST] key, and the display shows a con-
tent of the next item.
After that, the operator program the next set up item.
After that, the operator program the next set up item.
If a set up ends, it pushes [TL] key.
It shows the list of programmable data by this method (“Direct key entry
type”) on the next page.
It shows every set up item and example of display to the following.
<KEY SEQUENCE>
<DEPT>
<PLU>
KEY
CONTENTS OF USE
a Numerical key (0, 1 to 9) Used for numerical number entry.
b Double-zero key ([00])
Used for parameter entry and character
code entry.
code entry.
c Clear key ([CL])
Used for cancel entry.
d Point key ([.])
Used for decimal point entry and
right moving entry (As right cursor key).
e Multiplication key ([X])
Used for left moving entry (As left cursor key).
f
Subtotal key ([ST])
Used for data decision entry.
g Finalization key ([TL])
Used for programming termination entry.
Function
key
Step
Programmable
data
Entry type
Default
(MRS)
DEPT
[DEPTn]
or
DEPT
code +
[DEPT#]
or
DEPT
code +
[DEPT#]
1
Text
(CHARACTER)
DEPT.
xx
2
Price
(NUMERIC)
0
3
Entry type
(TOGGLE)
OPEN
4
Selection of TAX1
(TOGGLE)
(
*
1)
5
Selection of TAX2
(TOGGLE)
(
*
1)
6
Selection of TAX3
(TOGGLE)
(
*
1)
7
Selection of TAX4
(TOGGLE)
(
*
1)
8
Registration type
(TOGGLE)
NORMAL
9
Group no.
(NUMERIC)
(
*
1) (
*
2)
10
Limitation digits
(NUMERIC)
8
(
*
1) DEPT01 - 10
: VAT 1 / Group 1
DEPT11 - 20 : VAT 2 / Group 1
DEPT21
: VAT 1 / G ro u p
10
10
DEPT22 - 99 : VAT 1 / Group 1
(
*
2) Group 1-9
: (+) department
Group 10
: (-) department
Group 11
: (+) Hash department
Group 12
: (-) Hash department
Function
key
Step
Programmable
data
Entry type
Default
(MRS)
PLU
PLUn
or
PLU
code +
[ P L U /
SUB]
or
PLU
code +
[ P L U /
SUB]
1
Text
(CHARACTER) PLU. xxxx
2
Price
(NUMERIC)
0
3
Dept code
(NUMERIC)
01
4
Sign
(TOGGLE)
(+)
5
Type
(TOGGLE)
PLU
Click on the first or last page to see other XE-A303 (serv.man3) service manuals if exist.