 XEA-203 / 213 
Questions and Answers
 
 
 
 
 
Q. What is the size of the graphic logo? 
A. Size: 288 dots (w) x 130 dots (h) 
Color: black and white 
Black Rate  
- Total black rate: 35% or lower 
- Local black rate: The black rate of a horizontal dot line is 55% or less. 
 
Q. What size paper rolls are used on this model? 
A. Paper roll: Width: 57.5 ± 0.5 mm 
    Max. diam.: 80 mm 
    Quality: High quality (0.06 to 0.08 mm thickness) 
 
Q. What is the purpose of the USB port? 
A. The USB is used when running the PC-Link software, this is a very basic programming tool 
available from your supplier. 
 
Q. Can you tell me how to take a Sales Reset report which contains only the Department 
details? 
A. It is not possible to take a report on the printer that contains departments only. There are 
other Sharp ECR that can be purchased through our dealer network that can do this. 
 
Q. Can you tell me how to turn the receipt OFF/ON 
A. Enter the RCPT Key in the OP X/Z Position this will toggle the receipt from On to OFF  
 
 
Q. Can you tell me how to program my XEA213 for copy receipt? 
A. You have a key marked MA please insert this into the mode lock to start.  
Turn the MA Key to the Z/PGM position.  
Enter ST.  
Enter 63, using the numeric buttons 
Enter the X button.  
Using the numeric buttons enter 01010001 (see page 68 Op Manual for complete table) 
Enter ST. 
Enter TL/NS to complete 
 
 
Q. Can you tell me how to prevent my zero value PLU items being printed on the sales 
reports 
A. Your machine defaults to zero skip, see table below, however it may have been changed  
 
Please note, it may be useful to refer to the Electronic 
Version of both the User and Programming Manual. 
Please use the Search function within Adobe Acrobat 
 
 
 
 
 
 
You have a key marked MA please insert this into the mode lock to start.  
Turn the MA Key to the PGM position.  
Enter ST.  
Enter 6, using the numeric buttons 
Enter the X button.  
Using the numeric buttons enter 11000111  
Enter ST. 
Enter TL/NS to complete
 
Return the MA key to the REG position to operate 
 
Q. The sales figures are not resetting, they are continually accumulating. 
A. To reset the various sales report the procedure is to Enter the . (decimal point) key before 
the selected report, if the . (decimal point) key is not Entered the sales totals will not be 
reset. 
 
Example for Z1 General Report 
 
Turn Key to X1/Z1 
Press . (decimal point) 
Press TL/NS 
 
Q. Can I set Zero Skip in reports to save paper? 
A. You have a key marked MA please insert this into the mode lock to start.  
Turn the MA Key to the PGM position.  
Enter ST.  
Enter 6, using the numeric buttons 
Enter the X button.  
Using the numeric buttons enter 11000111  
Enter ST. 
Enter TL/NS to complete 
Return the MA key to the REG position to operate 
 
 
 
Q. Can you tell me how to program the rate for the VAT1. 
A. You have a key marked MA insert this into the mode lock to start.  
Turn the MA Key to the PGM position. 
Enter ST  
Enter 9, using the numeric buttons 
Enter X 
Enter 1 using the numeric buttons (Auto Vat rate) 
Enter X 
Enter 17.5 
Enter ST  
Enter TL to complete 
Return the MA key to the REG position to operate 
 
 
 
 
 
 
Q. Can you tell me how to delete a VAT1 rate 
A. You have a key marked MA insert this into the mode lock to start.  
Turn the MA Key to the PGM position. 
Enter ST 
Enter 9 (from the numeric buttons) 
Enter X 
Enter 1 
Enter X 
Enter 
 
Enter TL/NS 
 
 
 
Q. Can you tell me how to set my Department to be Auto VAT1. 
A. You have a key marked MA insert this into the mode lock to start.  
Turn the MA Key to the PGM position.  
Enter Dept number (using Numeric Keys) 
Press Dept # 
Enter ST 
Enter ST 
Enter ST 
Enter the [00] key to change to YES 
Enter ST 
Enter TL/NS 
Return the MA key to the REG position to operate 
 
 
       
Q. Can you tell me how to enter training mode and then cancel it afterwards? 
A. You have a key marked MA please insert this into the mode lock to start.  
Turn the MA Key to the PGM position.  
Enter ST.  
Enter 86, using the numeric buttons 
Enter the X button.  
Enter the chosen training Clerk Number (To cancel training clerk enter 0) 
Enter ST. 
Enter TL/NS to complete
 
Return the MA key to the REG position to operate 
 
 
 
Q. Can you tell me how to prevent the REFUND button in REG position to operate 
A. You have a key marked MA please insert this into the mode lock to start.  
Turn the MA Key to the PGM position.  
Enter ST.  
Enter 5, using the numeric buttons 
Enter the X button.  
Enter 00000101, using the numeric buttons 
Enter ST.  
Enter TL/NS to complete.  
Return the MA key to the REG position to operate 
 
 
 
 
Q. Can you tell me how to make a PLU an open entry type? 
A. You have a key marked MA insert this into the Mode lock.  
Turn the mode lock to the PGM position.  
Press the PLU (required for programming).  
Press ST  
Press ST  
Press ST  
Using the numeric buttons press 00. (Until subdept appears).  
Press ST 
Press TL/NS to finish. 
 
 
Q. Can you tell me how to program a preset price and name to a PLU? 
A. You have a key marked MA insert this into the Mode lock.  
Turn the mode lock to the PGM position.  
Press the PLU (to program).  
Using the numeric buttons press 00  
Using the text buttons enter the name.  
Press ST.  
Using the numeric buttons enter the price (without decimal point).  
Press ST 
Press TL/NS to finish.  
Return the mode lock to the REG position. 
 
Q. Can you tell me how to change a PLU key into a Department Key? 
A. You have a key marked MA insert this into the Mode lock.  
Turn the key to the PGM position. 
Press the PLU key you wish to change 
Press [00]  
Enter text for Key Name 
Press ST 
Press ST 
Enter Department Number 
Press ST 
Press [00] until SUBDEPT is shown on the display 
Press ST 
Press ST/TL 
 
 
Q. Can you tell me how to program a name and price to a Department 
A. You have a key marked MA insert this into the Mode lock.  
Turn the key to the PGM position.  
Press the DEPARTMENT button.  
Using the numeric buttons enter the 00  
Using the text buttons enter the name (max 12 characters).  
Press ST.  
Using the numeric buttons enter the price (without decimal point).  
Page of 9
Display

Download Sharp XE-A213 (serv.man7) FAQ

Here you can read online and download Sharp XE-A213 (serv.man7) FAQ in PDF. XE-A213 (serv.man7) faq will guide through the process and help you recover, restore, fix, disassemble and repair Sharp XE-A213 (serv.man7) ECR. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.