DIAGNOSTIC PROGRAM
– 18 –
14) AD CONVERSION PORT TEST
1 Key operation
160 
2 Test procedure
The test program displays the voltage of each AD conversion port.
The display is converted into each unit.
The test is terminated when any key is pressed.
Head temperature: XXX (°C)
Head voltage
: YYY (V)
Battery voltage
: ZZZ (V)
3 End of testing
The test is terminated when any key is pressed. 
15) USB TEST 1 (ID/ ADDRESS PRINT)
*Before performing this test, you must install driver to your PC.
The driver is included in UKOG-2379RCZZ and UKOG-2380RCZZ.
1 Key operation
520 
2 Test procedure
The USB revision, the vendor ID, the product ID, and the device
address assigned by the host are printed. 
3 Check:
The completion print.
4 End of testing
The test will automatically be terminated and the printer prints as fol-
lows.
<Print>
No print is made on the journal side and the receipt side. 
PO
OP display
T : X X X V : Y Y Y B : Z Z Z
 
160 
HEAD  TEMP                      XXX 
HEAD VOLTAGE             XXX 
BATTERY VOLTAGE          XXX 
PO
LCD display
U S B   T E S T 1           5 2 0
75$4GX8GT:::
8'0&14+&:::
241&7%6+&:::
&'8+%'#&&4'55:::
1 When HOST is connected: 
1~127
When HOST is not connected: 
0