40
Data transmission status is shown as follows.
Number
Meaning
Conceivable cause
0
Communication is successfully completed.
3
FDS file access error
Program bug or
PC has some trouble about file access.
4
TEXT file access error
Program bug or
PC has some trouble about file access.
11
text – binary exchange error
Program bug or data error.
21
protocol error
Program bug.
23
FDS packet data error.
Communication data lost.
31
DSR signal off error
There is some trouble in connection.
32
DCD signal off error
There is some trouble in connection.
33
DCD signal on error
There is some trouble in connection.
34
CTS signal off error
There is some trouble in connection.
35
Not connected
There is some trouble in connection.
36
ECR has been sent EOT.
Configuration mismatch between PC and
ECR.
38
Retry over error
ECR doesn't respond.
39
Time out error
ECR doesn't respond.
40
Not connected
There is some trouble in connection.
41
Connection has been established.
Program bug.
50
Program error
Program bug.
55
Memory allocate error
Program bug.
Click on the first or last page to see other XE-A207 (serv.man5) service manuals if exist.