XE-A202 (serv.man3). Operation Manual - Sharp ECR User Guide / Operation Manual. Page 64

Read Sharp XE-A202 (serv.man3) User Guide / Operation Manual online

62
OVERRIDE ENTRIES
Programmed limit for functions (such as for maximum amounts) can be overridden by making an entry in the
MGR mode.
In this example, the register has been programmed not to allow
discounts entries over 1.00.
REG mode
1500 
#
entries
250 
-
...Error
l
Turn the mode switch
to the MGR position.
250 
-
Return the mode switch
to the REG position.
A
Print
Key operation example
REG
OPX/Z
MGR
PGM
X1/Z1
X2/Z2
1.
Turn the mode switch to the MGR position.
2.
Make an override entry.
CORRECTION AFTER FINALIZING A
TRANSACTION  (Void mode)
When you need to void incorrect entries that clerks cannot correct (incorrect entries found after finalizing a
transaction or cannot be corrected by direct or indirect void), follow this procedure:
1.
Turn the mode switch to the 
position using the manager key (MA), to enter 
into the void mode.
2.
Repeat the entries that are recorded on an incorrect receipt.  (All data on the
incorrect receipt is removed from register memory; the voided amounts are
added to the void mode transaction totalizer.)
Cancellation receipt
Incorrect receipt
REG
OPX/Z
MGR
PGM
X1/Z1
X2/Z2
 A202_4 FOR THE MANAGER  03.7.5 8:10 AM  Page 62