CONTENTS
Parts marked with "!" are important for maintaining the safety of the set. Be sure to replace these parts with specified
ones for maintaining the safety and performance of the set.
CODE : 00Z
SERVICE MANUAL
LEAD-FREE SOLDER MODEL
UP820F/SME
POS TERMINAL
UP-820N
 MODEL
UP-820F
      
(For “V” version)
<UP-820N>
<UP-820F>
LEAD-FREE SOLDER
SPECIAL CAUTIONS
CHAPTER 1. SPECIFICATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1
CHAPTER 2. OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 1
CHAPTER 3. SERVICE PRECAUTION . . . . . . . . . . . . . . . . . . . . . 3 - 1
CHAPTER 4. TOUCH PANEL CALIBRATION, MASTER RESET
AND PROGRAM RESET . . . . . . . . . . . . . . . . . . . . . 4 - 1
CHAPTER 5. DIAGNOSTICS SPECIFICATIONS . . . . . . . . . . . . . 5 - 1
CHAPTER 6. HARDWARE DESCRIPTION . . . . . . . . . . . . . . . . . . 6 - 1
CHAPTER 7. UP-I04EF HARD DESCRIPTION . . . . . . . . . . . . . . . 7 - 1
CHAPTER 8. DISASSEMBLY AND ASSEMBLY . . . . . . . . . . . . . . 8 - 1
CHAPTER 9. INSTALLATION OF OPTIONS. . . . . . . . . . . . . . . . . 9 - 1
CHAPTER10. CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . 10 - 1
CHAPTER11. PWB LAYOUT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 - 1
UP-820N/820F (V)   LEAD-FREE SOLDER
■  LEAD-FREE SOLDER
The PWB’ s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder. The
alphabet following the LF mark shows the kind of lead-free solder. 
Example:
(1) NOTE FOR THE USE OF LEAD-FREE SOLDER THREAD
When repairing a lead-free solder PWB, use lead-free solder thread. Never use conventional lead solder thread, which may cause a breakdown or an accident. 
Since the melting point of lead-free solder thread is about 40°C higher than that of conventional lead solder thread, the use of the exclusive-use soldering iron is rec-
ommendable. 
(2) NOTE FOR SOLDERING WORK
Since the melting point of lead-free solder is about 220°C, which is about 40°C higher than that of conventional lead solder, and its soldering capacity is inferior to
conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land separation or may exceed the heat-resistive tem-
perature of components. Use enough care to separate the soldering iron from the PWB when completion of soldering is confirmed. 
Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently.  
If different-kind solder remains on the soldering iron tip, it is melted together with lead-free solder. To avoid this, clean the soldering iron tip after com-
pletion of soldering work. 
If the soldering iron tip is discolored black during soldering work, clean
and file the tip with steel wool or a fine filer. 
■ SPECIAL CAUTIONS 
Target model : UP-820N/UP-820F
Special cautions for production and servicing are described below.
(1) TOUCH PANEL
•  Since transparency is the vital factor of the transparent touch panel, use a great care not to put fingerprints or dirt on the transparent touch panel.
Use clean finger sucks, gloves, and a mask, and never touch the visible area. 
•  Do not apply a pressure to the pressure-inhibit area of the touch panel when assembling and handling. 
•  Since the glass edges are not chamfered and there are some sharp edges, always use finger sucks or gloves when handling. 
[Inhibition]
•  Never hold the flexible pattern section of the transparent touch panel in order to maintain the reliability.
•  Never put a touch panel over another in order to prevent them from scratching. 
•  Never put a heavy material, a hard material, or a sharp material on the transparent touch panel. 
• To remove dirt from the surface of the transparent touch panel, use soft cloth immersed in ethyl alcohol. If, however, ethyl alcohol soaks into the
attachment section of the film and the glass, separation or malfunction may occur. Use enough care for it. 
(2) PRINTER MECHANISM
•  If there is a scratch or dirt on the platen roller or the platen drive wheel, defective printing may occur. If an external pressure is applied to the plate
section, it may be deformed easily. Use enough care when assembling and handling. 
5mm
Lead-Free
Solder composition 
code (Refer to the 
table at the right.)
<Solder composition code of lead-free solder> 
Solder composition
Sn-Ag-Cu
Sn-Ag-Bi
Sn-Ag-Bi-Cu
Sn-Zn-Bi
Sn-In-Ag-Bi
Sn-Cu-Ni
Sn-Ag-Sb
Bi-Sn-Ag-P
Bi-Sn-Ag
a
b
z
i
n
s
p
Solder composition code
a
UP-820N/820F (V)   PRECAUTION
•  If an external pressure is applied to the lever, it may be deformed. Use enough care when assembling and handling. 
• When fingers come close to the thermal head in installation or removal of the printer or in paper replacement, static electricity may damage the
heating element and the IC’s. To prevent against this, be sure to use charging protection as well as human body earth before handling. Use extreme
care for the heating element on the thermal head surface and the thermal head control terminal. 
•  Be careful not to apply an extra force to the thermal head control terminal, or the connector may be damaged. 
•  When connecting or disconnecting the connector, be sure to turn OFF the power and disconnect the AC plug from the power outlet. 
(3) LCD UNIT AND INVERTER UNIT
•  When connecting or disconnecting the cable, be sure to turn OFF the power and disconnect the AC plug from the power outlet in order to prevent
the circuit parts from breakage.  At that time, hold the connector on the PWB side and connect or disconnect the cable in order not to apply an
excessive stress to the PWB. 
•  When assembling a unit, use enough care not to warp or twist it. 
• When handling, be sure to use human body earth to remove static electricity.  Of course, the normal handling cares for electronic parts must be
observed. (Static electricity, shock, heat, moisture, etc.)
•  When removing the scratch protection film (laminate film) of the LCD panel surface, static electricity may be generated. When removing, therefore,
discharge static electricity (by discharge blow) and remove slowly. 
•  Since the LCD panel surface (deflecting plate) is easily starched, use great care not to touch it with a hard or sharp material.
•  If a water drop remains on the LCD panel, it may cause discoloration or stain. Clean and remove it at once. 
•  When the LCD panel surface is stained, clean with soft cloth or absorbent cotton.
•  Since the LCD backlight section and the inverter unit are applied with a high voltage, they may cause an electric shock. When repairing or replacing
the lamp, be sure to turn OFF the power before executing the work. 
•  When cleaning the panel surface, grip a Dusper with clips, soak it in ligroin solution, and wipe and clean the panel vertically and horizontally. Do not
apply an excessive force, and do not move the Dusper in a circle or do not scrub. 
(4) KEYBOARD
•  Since transparency and maneuverability are important factors for the key sheet rubber, use finger sucks or gloves when handling. Do not use a hard
or sharp material to operate it. 
•  If water or oil is attached to the key sheet rubber, it may cause discoloration or stain. Clean and remove it at once. 
(5) GND WIRE, FERRITE CORE
•  Be sure to use only the GND wire and the ferrite core which are specified on the Parts Guide. 
•  If a hard shock is applied to the ferrite core, it may be damaged or broken. Use enough care to handle it. 
PRECAUTION
BATTERY DISPOSAL
Contains a Nickel Metal Hydride Battery pack. Must be Disposed of 
Property. Contact Local Environmental Officials for Disposal Instructions.
UP-820N/820F (V)
SPECIFICATION
1 – 1
CHAPTER 1. SPECIFICATION
1. RATING
2. APPEARANCE
3. KEYBOARD
(1) STANDARD KEYBOARD LAYOUT
<
UP-820N
>
Note: Free Key layout is available except Receipt and Journal paper
feed key.
<
UP-820F
>
Note: Free Key layout is available except Receipt and Journal paper
feed key.
(2) KEY TOP NAME
1 Standard key top
UP-820N
UP-820F
External dimensions
349 (W) 
×
 439 (D) 
×
 261 (H)mm
Weight
7.4kg
Power source
Official (normal) voltage and frequency
Power consumption
Operating : 67 W (max.)
Working temperatures
0 to 40 °C
<UP-820N>
<UP-820F>
5
4
3
2
1
10
15
14
13
12
11
20
19
18
17
16
9
8
7
6
JOURNAL
RECEIPT
RCPT
PLU/EAN
CUST
RA
RF
ST
TL
PO
AMT
MODE
HOME
CASH
#
PRICE
CHANGE
CRATE
MENU
AUTO
1
AUTO
2
POINT
REDEEM
DISC
GROUP2
DISC
GROUP1
INQ
CR#
CH#
CHARGE
CANCEL
ENTER
PAGE
DOWN
PAGE
UP
00
0
CL
1
3
2
4
5
6
7
8
9
JOURNAL
RECEPT
75
74
73
9
9
8
7
8
7
6
5
4
6
5
4
3
2
1
3
2
1
18
17
16
15
14
13
12
11
10
12
11
10
27
26
25
24
23
22
21
20
19
78
77
76
36
35
34
33
32
31
30
29
28
45
44
43
42
41
40
39
38
37
54
53
52
51
50
49
48
47
46
80
79
63
62
61
60
59
58
57
56
55
72
71
70
69
68
67
66
65
64
GLU
FINAL
NBAL
G.C.
RCPT
PLU/
SUB
00
0
000
CL
1
2
3
4
5
6
7
8
9
VAT
SHIFT
PRICE
SHIFT#
AUTO
MENU1
AUTO
MENU2
PLU
MENU1
PLU
MENU2
PLU
MENU3
PLU
MENU4
PLU
MENU5
PLU
MENU6
PLU
MENU7
MODE HOME
ENTER
PAGE
DOWN
PAGE
UP
CANCEL
BS
OPENED
GLU
FUNC
MENU
BT
CR#
CH#
ST
TL
KEY TOP
DESCRIPTION
UP-820N UP-820F
0-9, 00
Numeric keys
|
|
000
Numeric key
|
Decimal Point key
|
|
CL
Clear key
|
|
y
Multiplication key
|
|
RECEIPT 
2
Receipt paper feed key
|
|
JOURNAL 
2
Journal paper feed key
|
|
PAGE UP
Page up key
|
|
PAGE DOWN
Page down key
|
|
CANCEL
Cancel key
|
|
1 3 2  4
Cursor keys
|
|
ENTER
Enter key
|
|
p
Void Key
|
|
PLU/SUB
PLU/SUB dept. code entry
key
|
PLU/EAN
PLU/EAN key
|
(Dept) 1 to 12
Department 1 to 12 keys
|
(Dept) 1 to 20
Department 1 to 20 keys
|
(D-PLU) 1 to 80
Direct PLU 1 to 80 keys
|
AUTO MENU
1, 2
Automatic sequencing1 and
2 keys
|
|
CR#
Credit Menu Key
|
|
CH#
Check Menu Key
|
|
ST
Subtotal Key
|
|
TL
Total Key
|
|
FINAL
Tentative finalization key
|
OPENED GLU
Opened GLU list key
|
GLU
Guest Look-up key
|
NBAL
New Balance key
|
G.C.RCPT
Guest Check Receipt key
|
BS
Bill Separate key
|
VAT SHIFT
TAX Shift Key
|
PLU MENU1- 7
PLU MENU1- 7 Keys
|
FUNC MENU
Function Menu key
|
BT
Bill totalizer key
|
PRICE SHIFT
Price shift Menu key
|
MODE
Mode key
|
|
HOME
Home key
|
|
RA
Recived on Account key
|
PO
Paid out key
|
RF
Refund key
|
AMT
Amount key
|
CUST
Customer code entry key
|
CRATE MENU
Crate Menu key
|
PRICE 
CHANGE
Price Change key
|
INQ
Inquiry key
|
RCPT
Receipt key
|
Page of 89
Display

Download Sharp UP-800 (serv.man19) Service Manual (Repair Manual)

Here you can read online and download Sharp UP-800 (serv.man19) Service Manual in PDF. UP-800 (serv.man19) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp UP-800 (serv.man19) ECR. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.