UP-600, UP-700 (serv.man45). Documentation for Software Utilities - Sharp ECR Driver / Update. Page 5

Read Sharp UP-600 / UP-700 (serv.man45) Driver / Update online

3.2 02FD
No
Procedure on P.C. side
No
Procedure on POS side
1
Install “02FD.EXE” on the P.C.
ALL RAM Data UpLoad :   Go to "2"
ALL RAM Data DownLoad : Go to "9"
2
ALL RAM Data UpLoad
Connect P.C. and POS (CH2) via RS232. (Fig 1)
2
Enter the SRV mode.
Select "  2 SETTING ".
Select " 14 BACKUP SEND"
3
POS shows
4
Execute “02FD .EXE” on P.C.
*Don't execute the other Software at the same time.
5
Set the Communication method by "Setting" Button.
Push "OK" Button.
6
Push "POS -> PC" Button.
And Select the Receiving File.
7
Communication starts.
7
Push TL key.    P O S shows
8
UpLoad is comp leted.
The initial Window is shown.
Push "Exit" Button.
8
UpLoad is completed.
The SETTING menu is shown.
 SEND DATA                    ALL RAM
 SPEED               PROGRAMMED SPEED
BACKUP SEND
SENDING                 00000