CHAPTER 3. SERVICE PRECAUTION
1. IPL (Initial Program Loading) FUNCTION
1) INTRODUCTION
The application software of the UP-600/700 written in the flash ROM.
In the following cases, writing procedure of the application software
into the flash ROM is required
In the following cases, writing procedure of the application software
into the flash ROM is required
•
When the flash ROM is replaced with new one. The service part
flash ROM does not include the application software in it.
flash ROM does not include the application software in it.
•
When IPL writing is required because of change in the software.
The service part ofthe main PWB unit includes the flash ROM with
the application software written in it, and there is no need for
writing the application software when replacing the main PWB unit.
the application software written in it, and there is no need for
writing the application software when replacing the main PWB unit.
2) IPL PROCEDURE
There are two ways of IPL procedures.
•
IPL from P-ROM
•
IPL from PC communication (Please refer the next section)
The detailed descriptions on the above procedures are given below.
3) IPL FROM P-ROM
Master ROM-1 : VHI27801RAP1A
Master ROM-2 : VHI27801RAQ1A
Master ROM-2 : VHI27801RAQ1A
Before working on the installation, turn off the power switch on the
UP-600/700 and unplug the AC code from the AC outlet.
UP-600/700 and unplug the AC code from the AC outlet.
1. Insert a screwdriver into the slit on the right side of the lower
cabinet to remove the option RAM case.
2. IPL switch (SW301) on the IPL ROM PWB: Set the IPL switch
(SW301) to ON position.
3. Install to the IC sockets on the IPL ROM PWB.
4. Turn on the power switch of the UP-600/700.
5. The following display is shown and the IPL procedure is started.
When the procedure is completed, the message of "Completed" is
shown.
shown.
6. Turn off the power switch of UP-600/700.
7. Remove to the IC sockets on the IPL ROM PWB.
8. IPL switch (SW301) on the IPL ROM PWB: Set the IPL switch
(SW301) to OFF position.
9. Perform the master reset.
ROM1
ROM2
ROM1
ROM2
on
off
SW301
IPL from PROM
Version check…
Erase …
IPL write start
26 27 28 29 2A 2B
2C 2D 2E 2F 30 31
38 39 3A 3B 3C 3D
3E 3F
Verify …
IPL write completed
32 33 34 35 36 37
Completed.