UP-600/UP-700VPS 
 
43 
 
CHAPTER 5 : ENHANCEMENTS 
 
The following features are available when then 
“ENHANCEMENT” licence is enabled. 
 
Minimum Age for PLU / DEPT 
 
This feature allows you to assign a “minimum allowed 
age” for individual PLUs, EANs and D-EANS. It can 
also be set on a departmental basis. 
 
If the Minimum Age for a specific PLU is zero, the UP-
800 will check if a minimum age has been set for its 
associated department. If the age specified in both the 
PLU/EAN and the associated DEPT are zero, the item 
will sell without restriction. 
 
However, if either is non-zero, the UP-800 will prompt 
the operator to confirm that the customer is of the 
required age. The operator must respond with a simple 
YES or NO. If the response is YES, the item is 
registered in the normal way. If the response is NO, 
the UP-
800 will report a “ITEM PROHIBITED” error. 
 
Configuration 
 
SRV Mode 
– Enable “ENHANCEMENT” licence. 
 
 
 
 
 
 
 
 
 
 
 
At this point, the licence ID code will be displayed (not 
shown here). This must be passed to PRS in order to 
obtain an AUTH code, which must be entered into the 
ECR. 
 
After inputting the AUTH code, save the licence. 
 
 
 