ORDERMAN (serv.man4). UP-800 Sharp Service Manual for Orderman Connection - Sharp ECR Service Manual (repair manual). Page 9

Read Sharp ORDERMAN (serv.man4) Service Manual online

9
Programming at the UP-8x0
Orderman related programming has to be done only at that ECR where the base-station is
connected.
The programming of the UP-8x0 is divided in SRV- and PGM-programming.
SRV-Programming
CAUTION: During SRV-programming the communication to and from the base-station is
inhibited.
Orderman-Mandatory-Setting
Important: There are some programmings that are mandatory for Orderman-usage.
•  SRV#909D set to “Transaction in progress” = (-1)  0000.
•  UP-8x0 must be setup for overlapped-clerk-registrations.
This has to be done in SRV-mode via creation of the filing-group 107 and
parameter SRV#910A set to (+1)  1000.
•  SRV#919B “Entry of the number of guests” set to inhibit = (-2)  4100.
•  SRV#981C must be set to “Final key is Total Status Key in GLU” = (+2)  0020.
•  SRV#981C is recommended for “PLU group 0 setting” set to disable = (-1)  0020.
•  SRV#987D set to “No GLU Subset Code” = (-4)  0200.
•  PGM-2 – 02 Settings – 04 MEDIA – 3 CREDIT set for each available Credit the
“AMOUNT ENTRY” to COMPULSORY
Page of 19