ER-A610 (serv.man5). ERA610 Programming Manual - Sharp ECR Service Manual (repair manual). Page 48

Read Sharp ER-A610 (serv.man5) Service Manual online

[JOB#2620, 2621]
STACK REPORT 1 and 2
JOB#2620: STACK REPORT 1
JOB#2621: STACK REPORT 2
XX:
 JOB#
SSSSSS:
 Start code
EEEEEE:
 End code
JOB#
REPORT NAME
TYPE
00
General
09
All EAN
04
EAN stock
07
EAN zero sales
08
EAN minimum stock
10
DEPT./GROUP
13
DEPT. All group
20
PLU
RANGE
23
PLU group total
24
PLU stock
RANGE
27
PLU zero sales
28
PLU minimum stock
RANGE
30
Transaction
31
CID
32
Commission sale
33
Tax
34
Chiff
40
All clerk
50
All cashier
60
Hourly
RANGE (only X report)
70
Daily net
85
Customer
RANGE
87
Customer non-access
88
customer no payment
[
∗ ∗
]
Max. 70 step are programmable. "1 step" means the memory size
used for one no range type JOB#.
The RANGE-1 type JOB# means "8 steps".
The RANGE-2 type JOB# means "16 steps".
The range type JOB# means "8 steps".
For example)
The memory size for programming JOB#00, 20 and 50 is 10 steps.
(ie. 1 step for JOB#00, 8 step for JOB#20, and 1 step for JOB#50. )
[JOB#2630, 2631, 2632]
SECRET CODE PROGRAMMING
#2630:  PGM1 mode
#2631:  X1/Z1 mode
#2632:  X2/Z2 mode
If "0" is entered, "compulsory secret code entry" is canceled.
MRS = 0
[JOB#2641]
MESSAGE TEXT PROGRAMMING
X: Message No. = 1~50
Message 
No.
Description
MRS
1
Registration error
ENTRY ERROR
2
Misoperation error
MISOPERATION
3
Desired code is not
programmed yet.
NO RECORD
4
Paper empty
PAPER EMPTY
5
Secret code error
SECRET CODE
6
Code is not free
NOT FREE
7
Memory is full
MEMORY FULL
8
Insert slip paper
INSERT SLIP
9
The clerk has enterd a code for
which he or she is not
authorized.
NO AUTHORITY
10
(reserved)
11
Compulsory of pushing the
SBTL key
SBTL COMPUL.
12
Compulsory of tendering
TEND COMPUL.
13
Compulsory of PB entry
PB COMPUL.
14
Compulsory of SCM entry
SCM COMPUL.
15
Compulsory of guest# entry
GUEST COMPUL
16
(reserved)
17
IRC non reset error
NON RESET
18
Retry message
RETRY ?
19
After Z1 report
ENTRY ERR Z
20
KP off line
OFF LINE
21
KP motor lock
MOTOR LOCK
22
Overlaped clerk error
CLK ERROR
23
Cashier resetting over error
ENTRY ERR CA
24
Clerk reseting over error
ENTRY ERR CK
25
Set slip paper again
SLIP SET
26
File type error
TYPE ERROR
27
Power off
POWER OFF
28
In line busy
IRC BUSY
29
In line error
IRC ERROR
30
Tendering compulsory error for
tip
TIP ERROR
31
(reserved)
32
The clerk key is not pushed or
inserted.
NOT ASSIGNED
33
The clerk key is changed in the
transaction.
NOT CHANGE
34
Overflow limitation
OVER LIMIT.
35
The open price entry is inhibited.
INH. OPEN PR
36
The unit price entry is inhibited.
INH. UNIT PR
37
The direct non-tendering
finalization after previous tender
entry is inhibited.
NOT NON-TEND
38
Read error of Scale
SCALE ERROR
39
Power-off duaring VP of
Euro/French check and Slip
paper feed
P-OFF IN VP
2620
2621
XX
SSSSSS
ST
TL
EEEEEE
All delete
No range
Next JOB# (max.=20)
X
X
X
2630,2631,2632
XXYY
TL
0
X
2641
TL
XX
Space
X
X
Character key
ST
Message No.
 47 
Page of 60
Display