ER-A610 (serv.man5). ERA610 Programming Manual - Sharp ECR Service Manual (repair manual). Page 11

Read Sharp ER-A610 (serv.man5) Service Manual online

#920-D:
1. Machine assignment set up.
1. Assignment
920-D
Standalone
0
Sattellite
1
Master
2
Backup master
3
[JOB#921] NOT USED : MRS = 0000
[JOB#922] MRS = 0000: INLINE PROGRAMMING
AREA
#922-A, B: Not used (Fixed at "00")
#922-C, D: 1. Transmission speed and Carrier-off waiting time
Transmission speed
Carrier-off waiting time (mSec)
922-CD
480K BPS
3.2
01
6.4
02
9.6
04
12.8
00
1M BPS
1.6
09
3.2
10
4.8
12
6.4
08
[JOB#923] MRS=0010: INLINE PROGRAMMING
AREA
#923-A, B:  1. The record number for request of T-LOG polling (Set-
ting for satellite)
1. The record number for request of T-LOG polling
923-A, B
00
99 (
×
 100)
00
99
#923-C:
1. T-LOG function
1. T-LOG function
923-C
Not
0
Exit
1
#923-D:
1. Polling cycle
1. Polling cycle (second)
923-D
0
9 (Sec.)
0
9
[JOB#924] MRS = 1400 : INLINE PROGRAMMING
AREA
#924-A:
1. Report printing when consolidation daily and periodic
cashier reading or resetting is taken.
2. PLU save file
1. Report printing when
consolidation daily and
periodic cashier reading or
resetting is taken.
2. PLU save file
929-4
Printing of report on individual
register
Not
0
Exist
1
Printing of both i.e. reports on
individual machines and
consolidation report on the
entire system
Not
4
Exist
5
#924-B:
1. Save file exept for PLU
Programming whether or not to lock REG-mode en-
tries after individual daily total resetting
2. Locking after clerk resetting
3. Locking after term clerk resetting
1. Save file
exept for
PLU
2. Locking
after clerk
resetting
3. Locking
after term
clerk
resetting
924-B
No
Yes
Yes
0
No
1
No
Yes
2
No
3
Yes
Yes
Yes
4
No
5
No
Yes
6
No
7
#924-C:
Programming whether or not to lock REG-mode entries
after individual dailytotal resetting when the system has no
save file.
1. Locking after cashier resetting
2. Locking after hourly resetting
3. Locking after general resetting
1. Locking
after cashier
resetting
2. Locking
after hourly
resetting
3. Locking
after
general
resetting
924-C
Yes
Yes
Yes
0
No
1
No
Yes
2
No
3
No
Yes
Yes
4
No
5
No
Yes
6
No
7
#924-D: Programming whether or not to lock REG-mode entries af-
ter individual periodic total resetting when the system has
no save file.
1. Locking after cashier resetting
2. Locking after hourly resetting
3. Locking after general resetting
1. Locking
after cashier
resetting
2. Locking
after hourly
resetting
3. Locking
after
general
resetting
924-D
Yes
Yes
Yes
0
No
1
No
Yes
2
No
3
No
Yes
Yes
4
No
5
No
Yes
6
No
7
 10 
Page of 60
Display