ER-A610 (serv.man2). ERA570 610 EFT Option Manual - Sharp ECR Service Manual (repair manual). Page 2

Read Sharp ER-A610 (serv.man2) Service Manual online

CHAPTER 1. General
The ERA57EFT and ERA61EFT have been produced to en-
able connection of a De La Rue Fortronic F85 credit authori-
sation terminal to the SHARP ER-A570 & ER-A610.
Components
The ERA57EFT consists of :-
1.
1pc 4meg EPROM (U033n)
2.
1pc 2meg EPROM (R033n)
The ERA61EFT consists of :-
1.
1pc 4meg EPROM (U034n)
2.
1pc 2meg EPROM (R034n)
Where n = Version Number
Hardware Requirements
The following optional units are required.
1.
F85
Fortronic F85 terminal
2.
ERAxxEFT
EPROMS (2)
3.
ERA5RS
RS232 interface PWB
N.B  It should be noted that the F85 terminal must have soft-
ware revision "LG7 03 15" or above installed. This can be
found on the display on initial power up.
Reference Documents
The following reference documents are required when setting
up the EFT system on the ERA570 or ERA610.
1.
ERA570 Programming Manual (00ZERA570VPME)
2.
ERA570 Option Manual
(00ZERA57VOSME)
3.
ERA610 Programming Manual (00ZERA610VPME)
4.
ERA610 Option Manual
(00ZERA61VOSME)
Cable Specification
The Fortronic Terminal is supplied with one of the following
connectors. 
1.
8 Pin Minature DIN to 9 Pin female D-Type
2.
RJ45 to 9 Pin female D-Type
The reason there are two different connectors on the F-85 is
because of CE regulations. When connecting to an existing
terminal an 8 Pin DIN socket will be found on the terminal, but
if a new terminal is supplied it will have RJ45 connectors.
The cables are available from the Sharp Parts Centre and the
specifications are as follows :-
8 Pin Minature DIN to 9 Pin female D-Type
When connecting the Fortronic F85 terminal with 8 Pin DIN
sockets to the ERA570 or ERA610 the following cable should
be used.
Note : Pins 1, 6 & 8 are joined together on ECR connector.
The pin connections (looking at the back of the F85) are :
Sharp Part Number for 8 Pin Minature DIN to 9 Pin female
D-Type
F858PINCABLE Price Code AU
6
3
SD
DSR
8
CTS
2
RD
ECR side (9 pin Female)
F85 8 Pin Din
1
5
GND
1 - Transmit Data
7
RTS
3 - In 1
8 - Ground
2 - Recieve Data
5 - Out 2 
DCD
1
2
3
4
5
6
7
8
ERA570 EFT Interface
1
Page of 13
Display