SSP SETTING ORDER
1) Input 959 X TL after turning to the PGM2 MODE, and then confirm the inputted SSP number.
(Refer to the printed example.)
2) When SSP-005 exists, delete it in the following sequence. (No inputting is needed in case it does not exists.)
After turning to the SRV MODE, input as follows.
993
→
•
→
X
→
5
→
TL
3) Turn to the SRV MODE and then input the SSP following the attached SSP Setting Data.
4) Check a printed receipt by comparing it with the set data.
5) In case an error or errors is/are found, whose SSP data should be corrected in the following sequence.
991
→
•
→
X
→
XXX
→
X
→
YYY
→
ST
→
TL
XXX: STEP number YYY: SSP data
6) Switch off and on by pulling out the AC plug and inserting it again.