ER-A570 (serv.man5). ERA570 Option Programming Manual - Sharp ECR Service Manual (repair manual). Page 8

Read Sharp ER-A570 (serv.man5) Service Manual online

Fig. 3-4 Types of packets
10. Transmission Procedure
1
Normal sequence
2
Abnormal sequence-1
(when there is a single data error)
3
Abnormal sequence-2
(when there are six successive data errors)
Communication is disabled due to full retry counts . . . "PW-OFF"
(power off) will be printed on the master unit.
4
Abnormal sequence-3 (when ACK is in error)
5
Abnormal sequence-4 (when RACK is in error)
Full ACK retry counts. If RACK were not detected after five retries
to send ACK, it assumes RACK to be in error, and so the receiving
operation terminates normally.
6
Abnormal sequence-5
(receiving side not enabled to receive data)
11. Terminal Number Assignment
when the IRC option is installed, an IRC terminal number must also
be supplied. This number is in the range of 1 to 254. The number is
specified in the PGM 2 mode at installation time. It is necessary to
specify an number for each device connected to the IRC including the
master. It should be noted that the IRC terminal number and the
register number are not related. Section 10 of this manual indicates
how this number is specified.
IRC terminal number (3 digits max.): *000 
 254
*000: OFF line machine
Register number (4 digits max.): *0 
 9999
    *0: can not be used in the IRC operation.
F
DATA
packet
DA
SA
0
CH NO
DLS
BCL
BCH
DATA
CRC
CRC
F
F
ACK
packet
DA
SA
1
CH NO
DLS
0
0
CRC
CRC
F
PACK
packet
NRDY
(Not ready)
packet
F
DA
SA
1
CH NO
DLS
0
0
CRC
CRC
F
F
DA
SA
1
CH NO
DLS
0
0
CRC
CRC
F
Control packet
Data
ACK
RACK
[Sequence]
[Receiving side]
Data
X
Data
ACK
RACK
(Retry)
NOTE:
X
Indicates an error.
15ms
(No ACK)
Data
X
Data
(Retry-1)
15ms
(No ACK)
X
Data
X
15ms
(No ACK)
(Retry-5)
(No ACK)
ACK
X
6ms
(No ACK)
ACK
Data
RACK
ACK-1
6ms
ACK-2
Data
RACK
X
ACK-5
Data
NRDY
1  5