RJ45 to 9 Pin female D-Type
When connecting the Fortronic F85 terminal with RJ45 sock-
ets to the ERA570 or ERA610 the following cable should be
used.
Note : Pins 1, 6 & 8 are joined together on ECR connector.
The pin connections (looking at the back of the F85) are :
Sharp Part Number for RJ45 to 9 Pin female D-Type
F85RJ45CABLE Price Code AU
Installation
To install the F85 credit authorisation terminal and ERA570 or
ERA610 the following steps should be taken :-
1.  Fit the ERA57EFT EPROMs :
 U033n is fitted in the main EPROM socket IC5
 R033n is fitted in the option EPROM socket IC7
OR
1.  Fit the ERA61EFT EPROMs :
 U034n is fitted in the main EPROM socket IC5
 R034n is fitted in the option EPROM socket IC7
(Note that ‘n’ denotes the version number)
2. Perform a MASTER RESET after fitting the new EPROMS.
3.
Fit the ERA5RS as specified in the ERA57/610 option
manual
4.
Connect the cable between the selected port (as set in
946-D) on the ERA5RS and the F85 terminal ( Port 1).
5.
To confirm that the EPROMs are fitted correctly and are
functioning, carry out a 959 x TL in PGM2 mode. The
ECR should report U033n & R033n on an ERA570, or
U034n & R034n on an ERA610.
HARDWARE
ECR - F85 Terminal
The baud rate on both devices must be set up to match each
other. The ECR is programmed to use a fixed rate of 2400
baud. Consult the F85 documentation or your Fortronic repre-
sentative regarding setting this up on the F85 terminal.
The F85 terminal must be set for :
 ECR Enabled
 F85 standard interface
 2400 baud
6
3
SD
DSR
8
CTS
2
RD
ECR side (9 pin Female)
F85 RJ45
1
5
GND
7 - Transmit Data
7
RTS
3 - In 1
4 - Ground
1 - Recieve Data
2 - Out 2 
DCD
Pin1
Pin8
ERA570 EFT Interface