Read Sharp ER-A470 (serv.man3) Service Manual online
[JOB#2614]
LOGO TEXT PROGRAMMING
X: 1
∼
6
1
(24 char.)
2
(24 char.)
3
(24 char.)
4
(24 char.)
5
(24 char.)
6
(24 char.)
Character can be entered by using character keys or numeric keys.
The key entry sequence for entering one character by numeric keys is
as follows:
The key entry sequence for entering one character by numeric keys is
as follows:
XXX
→
00
Key XXX:
Character
code
(3
digits)
Please refer to section 3.
MRS =
YOUR
RECE
IPT
THANK
YOU
SHARP
IS
THE BE
ST
NOTE: This programming is related to JOB# 912D programming.
Only when "6-line header instead of a stamp" is selected by
JOB# 912D programming, all 6 lines are programmable.
When "3-line header" is selected, upper 3 lines (1st-3rd line)
are programmable.
When "3-line footer" is selected, lower 3 lines (4th-6th line)
are programmable.
JOB# 912D programming, all 6 lines are programmable.
When "3-line header" is selected, upper 3 lines (1st-3rd line)
are programmable.
When "3-line footer" is selected, lower 3 lines (4th-6th line)
are programmable.
[JOB#2615]
Programming of the limits to TRY ST feed line and No. of times of
validation printing.
validation printing.
Y:
No. of times of validation printing
= 0
∼
9
X:
Feed line after depression
of differ ST key.
of differ ST key.
= 0
∼
9
MRS = 10
[JOB#2616]
OPTIONAL FEATURE
X: 1
MRS = 00000000
A:
OP X/Z report
A
Enable
0
Disable
1
B:
PO operation in REG mode
B
Enable
0
Disable
1
C: Not used (Fixed at "0")
D:
"RFND" key entry in REG mode
D
Enable
0
Disable
1
E:
Direct void function in REG mode
E
Enable
0
Disable
1
F:
Indirect void in REG mode
F
Enable
0
Disable
1
G:
Subtotal void in REG mode
G
Enable
0
Disable
1
H:
Refund VP
H
Non compulsory
0
Compulsory
1
2614
Character key
X
Position code
No change
ST
TL
2615
YX
0
TL
2616
ABCDEFGH
0
X
ST
TL
28