ER-A460 (serv.man19). ER02FD does not Function Correctly - Sharp ECR Technical Bulletin (repair manual). Page 2

Read Sharp ER-A460 (serv.man19) Technical Bulletin online

SSP INPUTTING ORDER
1) Turn to the SRV MODE, input 130
TL and confirm the ROM version number. 
(Refer to the Printed Example.)
2) Input the SSP in accordance with the attached SSP Inputting Data.
3) Check the printed receipt by comparing it with the Inputting Data.
4) In case an error is found, correct the SSP data in the following sequence.
991 
 [ 
 ] 
 [ X ] 
 XXX 
 [ X ] 
 YYY 
 [ST] 
 [TL]
                   XXX:  STEP number       YYY:  SSP data
5) Switch off and on by pulling out the plug and inserting it.
Printed example:
130
ROM
27020RAU1A
          RAU1A
The underlined part means
the ROM version number.
(In this example, the ROM
version number is RAU1A.)
2/5
Page of 5