ER-A450S (serv.man6). Programming Manual - Sharp ECR Service Manual (repair manual). Page 40

Read Sharp ER-A450S (serv.man6) Service Manual online

5) PLU PRESET PRICE SETTING
Mode: PGM1/PGM2
XXXXXX: PLU CODE (1 to 999999)
YYYYYY: UNIT PRICE (6 digits)
If the record of entered PLU code is not in PLU file at this program-
ming, it will be created in PLU file.
MRS = 0
If the [PLU] or [PLUn] key is depressed, programming mode is
changed from "PRICE PROGRAMMING" to "ATTRIBUTE PRO-
GRAMMING" and changed to "PLU ASSOCIATION PROGRAM-
MING" by depressing the same key again.
(Caution!!)
The associated department is changed if the operater depress
[DPTn] key instead of [PLUn] key by mis-operation at this timing.
6) PLU ASSOCIATION TO DEPARTMENTS
Mode: PGM1/PGM2
XXXXXX:
PLU CODE (1 to 999999)
YY:
Dept. code (1 to 50)
If the record of entered PLU code is not in PLU file at this program-
ming, it will be created in PLU file.
MRS = 01
If the [PLU] or [PLUn] key is depressed, programming mode is
changed from "PRICE PROGRAMMING" to "ATTRIBUTE PRO-
GRAMMING" and changed to "PLU ASSOCIATION PROGRAM-
MING" by depressing the same key again.
(Caution!!)
The associated department is changed if the operater depress
[DPTn] key instead of [PLUn] key by mis-operation at this timing.
Triple depression of [PLU] or [PLUn] key is necessary for the
first time.
7) PROGRAMMING OF PLU/SUBDEPT
Mode: PGM2
XXXXXX:
PLU CODE (1 to 999999)
A:
Sign
A
+
0
1
B:
Taxable6
B
Non taxable
0
Taxable
1
C:
Taxable5
C
Non taxable
0
Taxable
1
D:
Taxable4
D
Non taxable
0
Taxable
1
E:
Taxable3
E
Non taxable
0
Taxable
1
F:
Taxable2
F
Non taxable
0
Taxable
1
G:
Taxable1
G
Non taxable
0
Taxable
1
H:
Amount entry type
H
Inhibited
0
Open
1
Preset
2
Open and preset
3
Delete
4
If the record of entered PLU code is not in PLU file at this program-
ming, it will be created in PLU file.
MRS = 00000002
If the [PLU] or [PLUn] key is depressed, programming mode is
changed from "PRICE PROGRAMMING" to "ATTRIBUTE PRO-
GRAMMING" and changed to "PLU ASSOCIATION PROGRAM-
MING" by depressing the same key again.
(Causion!!) The associated department is changed if the oper-
ater depress [DPTn] key instead of [PLUn] key by
mis-operation at this timing.
Double depression of [PLU] or [PLUn] key is necessary for the
first time.
8) EAN PRESET PRICE SETTING
Mode: PGM1/PGM2
XXXXXXXXXXXXX: EAN code
YYYYYY:
Unit price (6 digits)
If the record of entered EAN code is not in EAN file at this program-
ming, it will be created in EAN file.
MRS = nothing ( Default = 0)
Default is a value which is set when new EAN record is created by
another programming JOB.
If the [EAN] key is depressed, programming mode is changed from
"PRICE PROGRAMMING" to "ATTRIBUTE PROGRAMMING" and
changed to "EAN ASSOCIATION PROGRAMMING" by depress-
ing the same key again.
Not changed
XXXXXX
PLU code
for next code
YYYYYY
PLU
PLUn
ST
TL
XXXXXX
PLU code
PLU delete
PLU
PLUn
for next code
DPTn
VOID
YY
Not changed
ST
TL
DEPT#
Not changed
XXXXXX
PLU code
for next code
ABCDEFGH
PLU
PLUn
TL
XXXXXXXXXXXXX
EAN
(Scanning)
YYYYYY
No change
TL
ST
2 – 25
Page of 49
Display

Click on the first or last page to see other ER-A450S (serv.man6) service manuals if exist.