4) Up-loading matrix for the satellite
      STATE
Initial
After receiving ID-ENQ and sending ACK.
After sending NAK
EVENT   
0
1
2
ID-ENQ
Satellite checks the terminal No.:If it is correct, satellite
sends ACK and goes to 1.
If it is not correct, satellite ignores the ID-ENQ.
Satellite checks the terminal No.:If it is correct, satellite
sends ACK and goes to 1.
If it is not correct, satellite ignores the ID-ENQ.
ACK
NAK
EOT
Satellite goes to 0.
(ERROR END)
TEXT
Satellite checks the text block, if the block is correct,
satellite sends ACK and goes to 3.
If it is not correct, Satellite sends NAK and goes to 2.
If transmission cannot be continued, satellite sends EOT
and goes to 0.
(ERROR END)
Satellite checks the text block, if the block is correct,
Satellite sends ACK and goes to 3.
If it is not correct, Satellite sends NAK and goes to 2.
If transmission cannot be continued, satellite sends EOT
and goes to 0.
(ERROR END)
TIME-UP
Satellite goes to 0.
(ERROR END)
Time-up is 7 seconds
Satellite goes to 0.
(ERROR END)
Time-up is 7 seconds
      STATE
After receiving text and sending ACK
After sending ENQ
After sending TEXT  
EVENT   
3
4
5
ID-ENQ
ACK
Satellite sends the text and goes to 5.
Satellite  sends  the  text  and  goes  to  5,  or  sends  the  EOT
and goes to 0.
(Normal END)
NAK
Resends the text and then goes to 5.
If satellite has resent the text two times, sends EOT and
goes to 0.
(ERROR END)
EOT
Satellite sends ENQ and goes to 4.
Resends the ENQ and then goes to 4.
If Satellite has resent the ENQ two times, sends EOT and
goes to 0.
(ERROR END)
Satellite goes to 0.
(ERROR END)
TEXT
Satellite checks the text block, if the block is correct,
satellite sends ACK and goes to 3.
If it is not correct, satellite sends NAK and goes to 2.
If transmission cannot be continued, satellite sends EOT
and goes to 0.
(ERROR END)
TIME-UP
The host goes to 0.
(ERROR END)
Time-up is 7 seconds
Resends the ENQ  and then goes to 4.
If satellite has resent the ENQ  two times, sends EOT and
goes to 0.
(ERROR END)
Resends the text and then goes to 5.
If satellite has resent the text two times, sends EOT and
goes to 0.
(ERROR END)
Time-up: Four seconds after sending of text.
Two second after sending of ENQ.
 – 10 –